m+Medelevator.RU
← Поиск публикаций
Journal of microbiological methods · 2019

Fast fluorometric enumeration of E. coli using passive chip.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kasap Esin Nagihan, Doğan Üzeyir, Çoğun Ferah, Yıldırım Ender, Boyacı İsmail Hakkı, Çetin Demet, Suludere Zekiye, Tamer Uğur, Ertaş Nusret

Аннотация

In this report, a passive microfluidic chip design was developed for fast and sensitive fluorometric determination of Escherichia coli (E. coli) based on sandwich immunoassay. Initially, magnetic nanoparticles (MNPs) and chitosan modified mercaptopropionic acid capped cadmium telluride (CdTe) quantum dots (QDs) were functionalized with E.coli specific antibody to form a sandwich immunoassay with the E. coli. The magnetic separation and preconcentration of the E.coli from the sample solution was performed in the vial. Conjugation of QDs to the magnetically captured E. coli and washing were performed using a passive type of microchip. The microfluidic chip consists of four microchambers connected to each other by microchannels which act as capillary valves. Signal measurement was performed at the last chamber by using a hand-held spectrofluorometer equipped with a fiber optic reflection probe. The selectivity of the method was tested with Enterobacter aerogenes (E. aerogenes) and Salmonella enteritidis (S. enteritidis), it was observed that these bacteria have no interference effect on E.coli determination. The calibration curve was found to be linear in the range of 101-105 cfu/mL with a correlation coefficient higher than 0.99. The limit of detection was calculated as 5 cfu/mL. The method was successfully applied to spiked tap and lake water samples. The results suggest that the developed method is applicable for on-site E. coli detection and offers several advantages such as large dynamic range, high sensitivity, high selectivity and short analysis time.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты