DOI 10.1016/j.avsg.2025.09.016

Медицинская библиотека · Annals of vascular surgery · 2025

Outcomes in Fenestrated and Branched Endovascular Aortic Repair Comparing Patients with Narrow Flow Lumen versus Standard Flow Lumen of the Paravisceral Aortic Segment.

DiLosa Kathryn, Patel Rohini J, Mathlouthi Asma, Zarrintan Sina, Malas Mahmoud, Al-Nouri Omar, Barleben Andrew

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Fenestrated/branched endovascular aortic repair (F/BEVAR) with commercially available devices require a paravisceral segment >20 mm. We compared commercial and physician-modified F/BEVAR outcomes in a narrowed flow lumen (NFL, <20 mm) to a standard flow lumen (SFL, ≥20 mm).

METHODS

We conducted a retrospective review of F/BEVAR repairs between 2016 and 2024. Primary outcome was technical success, and secondary endpoints were target vessel stability, type 1/3 endoleaks requiring reintervention, and major adverse events (MAEs).

RESULTS

A total of 136 patients underwent 138 repairs (75% male, 74 ± 10 years), 35 repairs (25%) were in NFL and 103 (75%) in SFL. Median visceral segment diameter was 24 mm (interquartile range [IQR] 19-29; 16 mm, IQR 15-18 in NFL; 28 mm, IQR 23-30 in SFL, P < 0.001). We observed 99% technical success. Mean fenestrations per repair was higher in NFL (3.1 vs. 1.5, P < 0.001), and mean branches was higher in SFL (2.1 vs. 0.7, P < 0.001). There were 24 (17%; 2 in NFL, 22 in SFL, P = 0.035) MAEs. There were nine branch vessel occlusions (three in NFL, six in SFL, P = 0.463) at a median follow-up of 516 days. Target vessel stability (86% in NFL vs. 84% in SFL, P = 0.757) and rate of reinterventions (2, 6% in NFL; 14, 14% in SFL, P = 0.209) did not differ significantly.

CONCLUSION

Custom F/BEVAR offers equivalent outcomes in complex anatomy with narrowed paravisceral flow lumens compared to on-label branched and fenestrated repairs in SFLs. Early results demonstrate reasonable target vessel stability and freedom from reintervention, though additional follow-up is needed.

Для цитирования: DiLosa Kathryn, Patel Rohini J, Mathlouthi Asma, Zarrintan Sina, Malas Mahmoud, Al-Nouri Omar, Barleben Andrew. Outcomes in Fenestrated and Branched Endovascular Aortic Repair Comparing Patients with Narrow Flow Lumen versus Standard Flow Lumen of the Paravisceral Aortic Segment.. Annals of vascular surgery. 2025. DOI: 10.1016/j.avsg.2025.09.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.