MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/neuros/nyy359

Медицинская библиотека · Neurosurgery · 2019

Postoperative Rigid Cervical Collar Leads to Less Axial Neck Pain in the Early Stage After Open-Door Laminoplasty-A Single-Blinded Randomized Controlled Trial.

Cheung Jason Pui Yin, Cheung Prudence Wing Hang, Law Karlen, Borse Vishal, Lau Yuk Ming, Mak Ling Fung, Cheng Aldous, Samartzis Dino, Cheung Kenneth Man Chee

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Cervical collars are used after laminoplasty to protect the hinge opening, reduce risks of hinge fractures, and avoid spring-back phenomena. However, their use may lead to reduced range of motion and worse neck pain.

OBJECTIVE

To investigate the clinical, radiological, and functional outcomes of patients undergoing single-door laminoplasty with or without collar immobilization.

METHODS

This was a prospective, parallel, single-blinded randomized controlled trial. Patients underwent standardized single-door laminoplasty with mini-plates for cervical myelopathy and were randomly allocated into 2 groups based on the use of collar postoperatively. Clinical assessments included cervical range of motion, axial neck pain (VAS [visual analogue scale]), and objective scores (short-form 36-item, neck disability index, and modified Japanese Orthopaedic Association). All assessments were performed preoperatively and at postoperative 1, 2, 3, and 6 wk, and 3, 6, and 12 mo. Comparative analysis was performed via analysis of variance adjusted by baseline scores, sex, and age as covariates.

RESULTS

A total of 35 patients were recruited and randomized to collar use (n = 16) and without (n = 19). There were no dropouts or complications. There were no differences between groups at baseline. Subjects had comparable objective scores and range of motion at postoperative time-points. Patients without collar use had higher VAS at postoperative 1 wk (5.4 vs 3.5; P = .038) and 2 wk (3.5 vs 1.5; P = .028) but subsequently follow-up revealed no differences between the 2 groups.

CONCLUSION

The use of a rigid collar after laminoplasty leads to less axial neck pain in the first 2 wk after surgery. However, there is no additional benefit with regards to range of motion, quality of life, and complication risk.

Для цитирования: Cheung Jason Pui Yin, Cheung Prudence Wing Hang, Law Karlen, Borse Vishal, Lau Yuk Ming, Mak Ling Fung, Cheng Aldous, Samartzis Dino, Cheung Kenneth Man Chee. Postoperative Rigid Cervical Collar Leads to Less Axial Neck Pain in the Early Stage After Open-Door Laminoplasty-A Single-Blinded Randomized Controlled Trial.. Neurosurgery. 2019. DOI: 10.1093/neuros/nyy359.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.