Arquivos brasileiros de oftalmologia · 2009
[Frontalis suspension with polytetrafluorethylene for the treatment of blepharoptosis].
Аннотация на английскомСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Silvério Juliana, Sugano Débora Mayumi, Lucci Lúcia Miriam Dumont, Rehder José Ricardo Carvalho Lima
Аннотация
PURPOSE: To evaluate the functional results and complications of the use of expanded polytetrafluoroethylene in frontalis suspension surgery for the treatment of blepharoptosis.
METHODS: Frontalis suspension procedure with polytetrafluoroethylene was performed between 2003 and 2007 on 23 patients (36 eyes) with blepharoptosis. An average follow-up time was 15.8 months (range, 3 to 36). Surgical technique used was described by Fox.
RESULTS: The causes of blepharoptosis found were: congenital in 20 patients (86.95%), blepharophimosis in 2 (8.69%) and traumatic in 1 (4.35%). At the first week of postoperatory 6 (26.08%) patients related palpebral asymmetry, 4 (17.39%) noticed local edema, 3 (13.04%) presented granulomas and 1 (4.35%) presented facial cellulitis on the ipsilateral frontal region. After 3 months of follow-up 3 (13.04%) patients related palpebral asymmetry and 1 (4.35%) persisted the granuloma.
CONCLUSION: Polytetrafluoroethylene - Model CV3, 6.0 (Gore-tex(R), W.L. Gore & Associates Inc, Flagstaff, AZ, EUA) is an adequate material with good functional results (86.9%), relatively few complications (4.35%) and insatisfaction (13.4%) that could be an alternative for fascia lata in the surgery of frontalis suspension for the treatment of blepharoptosis.
METHODS: Frontalis suspension procedure with polytetrafluoroethylene was performed between 2003 and 2007 on 23 patients (36 eyes) with blepharoptosis. An average follow-up time was 15.8 months (range, 3 to 36). Surgical technique used was described by Fox.
RESULTS: The causes of blepharoptosis found were: congenital in 20 patients (86.95%), blepharophimosis in 2 (8.69%) and traumatic in 1 (4.35%). At the first week of postoperatory 6 (26.08%) patients related palpebral asymmetry, 4 (17.39%) noticed local edema, 3 (13.04%) presented granulomas and 1 (4.35%) presented facial cellulitis on the ipsilateral frontal region. After 3 months of follow-up 3 (13.04%) patients related palpebral asymmetry and 1 (4.35%) persisted the granuloma.
CONCLUSION: Polytetrafluoroethylene - Model CV3, 6.0 (Gore-tex(R), W.L. Gore & Associates Inc, Flagstaff, AZ, EUA) is an adequate material with good functional results (86.9%), relatively few complications (4.35%) and insatisfaction (13.4%) that could be an alternative for fascia lata in the surgery of frontalis suspension for the treatment of blepharoptosis.