MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3346/jkms.2026.41.e34

Медицинская библиотека · Journal of Korean medical science · 2026

Real-World Outcomes of Hybrid Closed-Loop System Use in Korean Youth With Childhood-Onset Type 1 Diabetes.

Woo Hyun Ah, Jeong Su Jin, Lee Yun Jeong, Kim Hwa Young, Gu Minjeong, Kim Ji Young, Kim Jaehyun, Shin Choong Ho, Lee Young Ah

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Hybrid closed-loop (HCL) systems adjust basal insulin levels using real-time glucose levels obtained from continuous glucose monitors (CGM). This study evaluated the MiniMed 770G system in Korean youths with childhood-onset type 1 diabetes (T1D).

METHODS

Of the 457 patients followed-up for childhood-onset T1D for > 1 year at Seoul National University Children's Hospital and Seoul National University Bundang Hospital between February 2022 and May 2023, 20 patients (10 boys, 10 girls) who used a MiniMed 770G system for ≥ 3 months with a CGM active time of > 70% were enrolled. Glycemic outcomes, including glycated hemoglobin A1c (HbA1c), and CGM-derived metrics (time in range [TIR], time below range, time above range > 180 mg/dL and > 250 mg/dL [TAR 180 and TAR 250], and coefficient of variation [CV]) were analyzed. Generalized estimating equation (GEE) analysis compared glycemic outcomes between auto-mode users (> 85% and ≤ 85%) during the 1-year follow-up.

RESULTS

The median age at HCL initiation was 14.0 years (interquartile range [IQR], 11.2, 17.9), with a median diabetes duration of 6.5 years (IQR, 5.7, 8.9). The numbers of auto-mode (> 85%) users at 3, 6, 9, and 12 months were 10, 9, 9, and 7, respectively. Compared to auto-mode (≤ 85%) users, auto-mode (> 85%) users demonstrated 0.75 lower HbA1c (P = 0.037), 7.0 higher TIR (P = 0.015), 6.7 lower TAR 180 (P = 0.031), and 3.2 lower CV (P = 0.001) during the year using GEE analysis. In an analysis of auto-mode (> 85%) users, the median TIR, TAR, and CV significantly improved from 59% at baseline to 74.5% at 3 months (P = 0.008), and from 65% at baseline to 73% at 6 months (P = 0.012). Neither severe hypoglycemia nor diabetic ketoacidosis was observed throughout the year. The most common reasons for auto-mode exit were hyperglycemia and a lack of calibration.

CONCLUSION

Use of HCL system with auto-mode (> 85%) enhanced glycemic control in youth with childhood-onset T1D during the study period.

Для цитирования: Woo Hyun Ah, Jeong Su Jin, Lee Yun Jeong, Kim Hwa Young, Gu Minjeong, Kim Ji Young, Kim Jaehyun, Shin Choong Ho, Lee Young Ah. Real-World Outcomes of Hybrid Closed-Loop System Use in Korean Youth With Childhood-Onset Type 1 Diabetes.. Journal of Korean medical science. 2026. DOI: 10.3346/jkms.2026.41.e34.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.