Multicenter midterm follow-up results using the gore septal occluder for atrial septal defect closure in pediatric patients.

СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Grohmann Jochen, Wildberg Christian, Zartner Peter, Abu-Tair Tariq, Tarusinov Gleb, Kitzmüller Erwin, Schmoor Claudia, Stiller Brigitte, Kampmann Christoph

Аннотация

OBJECTIVES: To assess the safety and efficacy of the Gore Septal Occluder (GSO) used for device-closure of significant secundum-type atrial septal defects (ASD II) focusing on pediatric patients.

BACKGROUND: The GSO is a patch-like double disc device. Due to its design, it is assumed to be safe, even when implanted in ASDs with deficient retro-aortic rims.

METHODS: Multicenter retrospective analysis of consecutive children and adolescents with a GSO in situ for at least 12 months according to a 1- to 4-year midterm follow-up.

RESULTS: Hundred and seventy three pediatric patients were enrolled. At implantation, median age was 6 years (range 0.7-17.9), median body weight and length were 21 kg (6.4-95) and 119 cm (65-193). Median follow-up period was 20 months (range 12-51). ASD anatomy was comprised of single defects in 131 patients (76%), multi-fenestrated defects in 42 (24%), and deficient retro-aortic rims in 33 (19%). Follow-up confirmed an overall closure-rate of 95.4%. Small residual shunts were reported in eight patients (4.6%) without need for any re-intervention. Complications were classified as minor events both during the initial procedure (9 patients, 5.2%) and on follow-up (another 9 patients), including transient AV block II in three patients (1.8%) and four snare-retrievals (2.4%) during the initial procedure.

CONCLUSIONS: Periprocedural and midterm follow-up data have shown the GSO to be effective and safe for ASD device closure in children and adolescents. GSO may be considered the first-choice device in deficient retro-aortic rims and multi-fenestrated defects, when covering most of the atrial septum is necessary. © 2016 Wiley Periodicals, Inc.