Hypothermia or Machine Perfusion in Kidney Donors.

Malinoski Darren, Saunders Christina, Swain Sharon, Groat Tahnee, Wood Patrick R, Reese Jeffrey, Nelson Rachel, Prinz Jennifer, Kishish Kate, Van De Walker Craig, Geraghty P J, Broglio Kristine, Niemann Claus U

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Therapeutic hypothermia in brain-dead organ donors has been shown to reduce delayed graft function in kidney recipients after transplantation. Data are needed on the effect of hypothermia as compared with machine perfusion on outcomes after kidney transplantation.

METHODS

At six organ-procurement facilities in the United States, we randomly assigned brain-dead kidney donors to undergo therapeutic hypothermia (hypothermia group), ex situ kidney hypothermic machine perfusion (machine-perfusion group), or both (combination-therapy group). The primary outcome was delayed graft function in the kidney transplant recipients (defined as the initiation of dialysis during the first 7 days after transplantation). We also evaluated whether hypothermia alone was noninferior to machine perfusion alone and whether the combination of both methods was superior to each of the individual therapies. Secondary outcomes included graft survival at 1 year after transplantation.

RESULTS

From 725 enrolled donors, 1349 kidneys were transplanted: 359 kidneys in the hypothermia group, 511 in the machine-perfusion group, and 479 in the combined-therapy group. Delayed graft function occurred in 109 patients (30%) in the hypothermia group, in 99 patients (19%) in the machine-perfusion group, and in 103 patients (22%) in the combination-therapy group. Adjusted risk ratios for delayed graft function were 1.72 (95% confidence interval [CI], 1.35 to 2.17) for hypothermia as compared with machine perfusion, 1.57 (95% CI, 1.26 to 1.96) for hypothermia as compared with combination therapy, and 1.09 (95% CI, 0.85 to 1.40) for combination therapy as compared with machine perfusion. At 1 year, the frequency of graft survival was similar in the three groups. A total of 10 adverse events were reported, including cardiovascular instability in 9 donors and organ loss in 1 donor owing to perfusion malfunction.

CONCLUSIONS

Among brain-dead organ donors, therapeutic hypothermia was inferior to machine perfusion of the kidney in reducing delayed graft function after transplantation. The combination of hypothermia and machine perfusion did not provide additional protection. (Funded by Arnold Ventures; ClinicalTrials.gov number, NCT02525510.).

Для цитирования: Malinoski Darren, Saunders Christina, Swain Sharon, Groat Tahnee, Wood Patrick R, Reese Jeffrey, Nelson Rachel, Prinz Jennifer, Kishish Kate, Van De Walker Craig, Geraghty P J, Broglio Kristine, Niemann Claus U. Hypothermia or Machine Perfusion in Kidney Donors.. The New England journal of medicine. 2023. DOI: 10.1056/nejmoa2118265.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.