STUDY

OBJECTIVES

Obstructive sleep apnea (OSA) is characterized by repetitive pharyngeal collapse during sleep. However, the dynamics of pharyngeal narrowing and re-expansion during flow-limited breathing are not well described. The static pharyngeal tube law (end-expiratory area versus luminal pressure) has demonstrated increasing pharyngeal compliance as luminal pressure decreases, indicating that the airway would be sucked closed with sufficient inspiratory effort. On the contrary, the airway is rarely sucked closed during inspiratory flow limitation, suggesting that the airway is getting stiffer. Therefore, we hypothesized that during inspiratory flow limitation, as opposed to static conditions, the pharynx becomes stiffer as luminal pressure decreases.

METHODS

Upper airway endoscopy and simultaneous measurements of airflow and epiglottic pressure were performed during natural nonrapid eye movement sleep. Continuous positive (or negative) airway pressure was used to induce flow limitation. Flow-limited breaths were selected for airway cross-sectional area measurements. Relative airway area was quantified as a percentage of end-expiratory area. Inspiratory airway radial compliance was calculated at each quintile of epiglottic pressure versus airway area plot (tube law).

RESULTS

Eighteen subjects (14 males) with OSA (apnea-hypopnea index = 57 ± 27 events/h), aged 49 ± 8 y, with a body mass index of 35 ± 6 kg/m(2) were studied. A total of 163 flow limited breaths were analyzed (9 ± 3 breaths per subject). Compliances at the fourth (2.0 ± 4.7 % area/cmH2O) and fifth (0.0 ± 1.7 % area/cmH2O) quintiles were significantly lower than the first (12.2 ± 5.5 % area/cmH2O) pressure quintile (P < 0.05).

CONCLUSIONS

The pharyngeal tube law is concave (airway gets stiffer as luminal pressure decreases) during respiratory cycles under inspiratory flow limitation.

Для цитирования: Genta Pedro R, Edwards Bradley A, Sands Scott A, Owens Robert L, Butler James P, Loring Stephen H, White David P, Wellman Andrew. Tube Law of the Pharyngeal Airway in Sleeping Patients with Obstructive Sleep Apnea.. Sleep. 2016. DOI: 10.5665/sleep.5440.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.