MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4065/75.5.521

Медицинская библиотека · Mayo Clinic proceedings · 2000

Corticotropin- and thyrotropin-secreting pituitary microadenomas: detection by dynamic magnetic resonance imaging.

Smallridge R C, Czervionke L F, Fellows D W, Bernet V J

Клинический случайСтатьяПеревод в очереди

Аннотация

Hormone-secreting pituitary microadenomas are often not visible on magnetic resonance imaging (MRI). Diagnosis requires confirmatory endocrine test results and often an invasive procedure, inferior petrosal sinus sampling (IPSS). Improved pituitary imaging may eliminate the need for IPSS in some patients, as shown in the 2 women in this report. The first patient with hirsutism, weight gain, and hypertension had intermittent elevations of urinary free cortisol, abnormal results on a low-dose dexamethasone suppression test, and positive results on a dexamethasone-suppressed ovine corticotropin-releasing hormone test (corticotropin, increase of 122%; cortisol, increase of 118%). Gadolinium-enhanced MRI showed no focal lesion, but dynamic MRI (sequential images beginning immediately after contrast injection) revealed a right-sided 5-mm microadenoma, confirmed by transsphenoidal surgery. The second patient had a goiter, anxiety, increased free thyroxine and triiodothyronine levels, and a normal thyrotropin value with no response to thyrotropin-releasing hormone. Magnetic resonance imaging showed no lesion, but dynamic MRI detected an 8-mm microadenoma. Although about 8% to 10% of healthy persons have incidental pituitary lesions that are 3 mm or larger on MRI, identification of a distinct lesion and positive results on a dexamethasone-suppressed ovine corticotropin-releasing hormone test should decrease the probability of a false-positive result on an imaging study. We recommend that dynamic MRI be performed in any patient with a suspected microadenoma, before IPSS is performed.

Для цитирования: Smallridge R C, Czervionke L F, Fellows D W, Bernet V J. Corticotropin- and thyrotropin-secreting pituitary microadenomas: detection by dynamic magnetic resonance imaging.. Mayo Clinic proceedings. 2000. DOI: 10.4065/75.5.521.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.