BACKGROUND

Echocardiographically detected patent foramen ovale (PFO) has been associated with stroke/transient ischemic attack (TIA) in patients with cardiac implantable electronic devices (CIEDs). We sought to evaluate the relationship between echocardiographic characteristics and risk of stroke/TIA and mortality in CIED patients with PFO.

METHODS

In 6,086 device patients, PFO was detected in 319 patients. A baseline echocardiogram was present in 250 patients, with 186 having a follow-up echocardiogram.

RESULTS

Of 250 patients with a baseline echocardiogram, 9.6% (n = 24) had a stroke/TIA during mean follow-up of 5.3 ± 3.1 years; and 42% (n = 105) died over 7.1 ± 3.7 years. Atrial septal aneurysm, prominent Eustachian valve, visible shunting across PFO, baseline or change in estimated right ventricular systolic pressure (RVSP)/tricuspid regurgitation (TR), or maximum RVSP were not associated with postimplant stroke/TIA (P > 0.05). An exploratory multivariate analysis using time-dependent Cox models showed increased hazard of death in patients with increase in TR ≥2 grades (hazard ratio [HR] 1.780, 95% confidence interval [CI] 1.447-2.189, P < 0.0001), or increase in RVSP by >10 mm Hg (HR 2.018, 95% CI 1.593-2.556, P < 0.0001), or maximum RVSP in follow-up (HR 1.432, 95% CI 1.351-1.516, P < 0.0001). A significant increase (P < 0.001) in TR was also noted during follow-up.

CONCLUSIONS

In patients with CIED and PFO, structural and hemodynamic echocardiographic markers did not predict future stroke/TIA. However, a significantly higher TR or RVSP was associated with higher mortality.

Для цитирования: Ponamgi Shiva P, Vaidya Vaibhav R, Desimone Christopher V, Noheria Amit, Hodge David O, Slusser Joshua P, Ammash Naser M, Bruce Charles J, Rabinstein Alejandro A, Friedman Paul A, Asirvatham Samuel J. Endocardial Device Leads in Patients with Patent Foramen Ovale: Echocardiographic Correlates of Stroke/TIA and Mortality.. Pacing and clinical electrophysiology : PACE. 2017. DOI: 10.1111/pace.12985.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.