MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-010-1887-3

Медицинская библиотека · European radiology · 2010

Athletic injuries of the extensor carpi ulnaris subsheath: MRI findings and utility of gadolinium-enhanced fat-saturated T1-weighted sequences with wrist pronation and supination.

Jeantroux Jeremy, Becce Fabio, Guerini Henri, Montalvan Bernard, Le Viet Dominique, Drapé Jean-Luc

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To report the magnetic resonance imaging (MRI) findings in athletic injuries of the extensor carpi ulnaris (ECU) subsheath, assessing the utility of gadolinium-enhanced (Gd) fat-saturated (FS) T1-weighted sequences with wrist pronation and supination.

METHODS

Sixteen patients (13 male, three female; mean age 30.3 years) with athletic injuries of the ECU subsheath sustained between January 2003 and June 2009 were included in this retrospective study. Initial and follow-up 1.5-T wrist MRIs were performed with transverse T1-weighted and STIR sequences in pronation, and Gd FS T1-weighted sequences with wrist pronation and supination. Two radiologists assessed the type of injury (A to C), ECU tendon stability, associated lesions and rated pulse sequences using a three-point scale: 1=poor, 2=good and 3=excellent.

RESULTS

Gd-enhanced FS T1-weighted transverse sequences in supination (2.63) and pronation (2.56) were most valuable, compared with STIR (2.19) and T1-weighted (1.94). Nine type A, one type B and six type C injuries were found. There were trends towards diminution in size, signal intensity and enhancement of associated pouches on follow-up MRI and tendon stabilisation within the ulnar groove.

CONCLUSION

Gd-enhanced FS T1-weighted sequences with wrist pronation and supination are most valuable in assessing and follow-up athletic injuries of the ECU subsheath on 1.5-T MRI.

Для цитирования: Jeantroux Jeremy, Becce Fabio, Guerini Henri, Montalvan Bernard, Le Viet Dominique, Drapé Jean-Luc. Athletic injuries of the extensor carpi ulnaris subsheath: MRI findings and utility of gadolinium-enhanced fat-saturated T1-weighted sequences with wrist pronation and supination.. European radiology. 2010. DOI: 10.1007/s00330-010-1887-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.