MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00062-023-01265-3

Медицинская библиотека · Clinical neuroradiology · 2023

Diagnostic Accuracy of Epilepsy-dedicated MRI with Post-processing.

Urbach Horst, Scheiwe Christian, Shah Muskesh J, Nakagawa Julia M, Heers Marcel, San Antonio-Arce Maria Victoria, Altenmueller Dirk-Matthias, Schulze-Bonhage Andreas, Huppertz Hans-Juergen, Demerath Theo, Doostkam Soroush

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the diagnostic accuracy of epilepsy-dedicated 3 Tesla MRI including post-processing by correlating MRI, histopathology, and postsurgical seizure outcomes.

METHODS

3 Tesla-MRI including a magnetization-prepared two rapid acquisition gradient echo (MP2RAGE) sequence for post-processing using the morphometric analysis program MAP was acquired in 116 consecutive patients with drug-resistant focal epilepsy undergoing resection surgery. The MRI, histopathology reports and postsurgical seizure outcomes were recorded from the patient's charts.

RESULTS

The MRI and histopathology were concordant in 101 and discordant in 15 patients, 3 no hippocampal sclerosis/gliosis only lesions were missed on MRI and 1 of 28 focal cortical dysplasia (FCD) type II associated with a glial scar was considered a glial scar only on MRI. In another five patients, MRI was suggestive of FCD, the histopathology was uneventful but patients were seizure-free following surgery. The MRI and histopathology were concordant in 20 of 21 glioneuronal tumors, 6 cavernomas, and 7 glial scars. Histopathology was negative in 10 patients with temporal lobe epilepsy, 4 of them had anteroinferior meningoencephaloceles. Engel class IA outcome was reached in 71% of patients.

CONCLUSION

The proposed MRI protocol is highly accurate. No hippocampal sclerosis/gliosis only lesions are typically MRI negative. Small MRI positive FCD can be histopathologically missed, most likely due to sampling errors resulting from insufficient harvesting of tissue.

Для цитирования: Urbach Horst, Scheiwe Christian, Shah Muskesh J, Nakagawa Julia M, Heers Marcel, San Antonio-Arce Maria Victoria, Altenmueller Dirk-Matthias, Schulze-Bonhage Andreas, Huppertz Hans-Juergen, Demerath Theo, Doostkam Soroush. Diagnostic Accuracy of Epilepsy-dedicated MRI with Post-processing.. Clinical neuroradiology. 2023. DOI: 10.1007/s00062-023-01265-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.