MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/lary.29742

Медицинская библиотека · The Laryngoscope · 2021

Cochlear Implantation in Pediatric Patients With Enlarged Vestibular Aqueduct: A Systematic Review.

Benchetrit Liliya, Jabbour Nicolette, Appachi Swathi, Liu Yi-Chun, Cohen Michael S, Anne Samantha

СтатьяМетаанализСистематический обзорПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

OBJECTIVE(S): To describe cochlear implantation (CI) outcomes, with speech perception, auditory, language, and parent-reported auditory and speech behaviors, in children with an enlarged vestibular aqueduct (EVA) and incomplete partition type 2 (IP-II) and compare to control children without inner ear malformations (IEMs) and to determine cerebrospinal fluid gusher rates and effect on outcomes.

STUDY

DESIGN

Systematic review and meta-analysis.

METHODS

MEDLINE, Embase, Cochrane, and CINAHL databases were searched from inception to February 2020. Studies reporting relevant outcomes in children with EVA or EVA + IP-II and controls without IEMs undergoing CI were included. Mean differences in speech perception, auditory, and language scores between cases and controls were meta-analyzed. Gusher rates were determined by proportion meta-analyses.

RESULTS

Of 214 identified articles, 42 met inclusion criteria, evaluating 775 cases and 2,191 controls. Of -cases, 578 (74.6%) had EVA and 197 (25.4%) had EVA + IP-II. Cases showed a significant improvement in speech perception, auditory and language performance, comparable to controls. Parent-reported auditory and speech production behaviors outcomes were positive among cases and comparable to controls. Pooled gusher proportions in EVA and EVA + IP-II cases were 27.7% (95% CI: 17.6-39.1) and 48.6% (95% CI: 28.6-69.0), respectively, with a proportion difference of 20.9% (95% CI: 11.0-30.1). Gusher occurrence did not impact speech perception or language outcomes.

CONCLUSION

Outcomes in children with EVA or EVA + IP-II undergoing CI are favorable and largely comparable to outcomes in children with hearing loss undergoing CI without IEMs. Intraoperative gusher is more prevalent among children with EVA + IP-II as compared to iEVA. Gusher does not influence speech perception and language development outcomes.

LEVEL OF EVIDENCE: NA Laryngoscope, 132:1459-1472, 2022.

Для цитирования: Benchetrit Liliya, Jabbour Nicolette, Appachi Swathi, Liu Yi-Chun, Cohen Michael S, Anne Samantha. Cochlear Implantation in Pediatric Patients With Enlarged Vestibular Aqueduct: A Systematic Review.. The Laryngoscope. 2021. DOI: 10.1002/lary.29742.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.