DOI 10.1007/s10877-016-9878-9

Медицинская библиотека · Journal of clinical monitoring and computing · 2016

Effect of patent ductus arteriosus and patent foramen ovale on left ventricular stroke volume measurement by electrical velocimetry in comparison to transthoracic echocardiography in neonates.

Blohm Martin Ernst, Hartwich Jana, Obrecht Denise, Kersten Jan Felix, Singer Dominique

Сравнительное исследованиеСтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

This prospective single-center observational study compared impedance cardiography [electrical velocimetry (EV)] with transthoracic echocardiography (TTE, based on trans-aortic flow) and analyzed the influence of physiological shunts, such as patent ductus arteriosus (PDA) or patent foramen ovale (PFO), on measurement accuracy. Two hundred and ninety-one triplicate simultaneous paired left ventricular stroke volume (LVSV) measurements by EV (LVSVEV) and TTE (LVSVTTE) in 99 spontaneously breathing neonates (mean weight 3270 g; range 1227-4600 g) were included. For the whole cohort, the mean absolute LVSVEV was 5.5 mL, mean LVSVTTE was 4.9 mL, resulting in an absolute Bland-Altman bias of -0.7 mL (limits of agreement LOA -3.0 to 1.7 mL), relative bias -12.8 %; mean percentage error MPE 44.9 %; true precision TPEV 33.4 % (n = 99 aggregated data points). In neonates without shunts (n = 32): mean LVSVEV 5.0 mL, mean LVSVTTE 4.6 mL, Bland-Altman bias -0.4 mL (LOA -2.8 to 2.0 mL), relative bias -8.2 %; MPE 50.7 %; TPEV 40.9 %. In neonates with shunts (PDA and/or PFO; n = 67): mean LVSVEV 5.8 mL, mean LVSVTTE 5.0 mL, bias -0.8 mL (LOA -3.1 to 1.5 mL), relative bias -14.8 %, MPE 41.9 %, TPEV 29.3 %. Accuracy was affected by PDA and/or PFO, with a significant increase in the relative difference in LVSVEV versus LVSVTTE: Subjects without shunts -2.9 % (n = 91), PFO alone -9.6 % (n = 125), PDA alone -14.0 % (n = 12), and PDA and PFO -18.5 % (n = 63). Physiological shunts (PDA and/or PFO) in neonates affect measurement accuracy and cause overestimation of LVSVEV compared with LVSVTTE.

Для цитирования: Blohm Martin Ernst, Hartwich Jana, Obrecht Denise, Kersten Jan Felix, Singer Dominique. Effect of patent ductus arteriosus and patent foramen ovale on left ventricular stroke volume measurement by electrical velocimetry in comparison to transthoracic echocardiography in neonates.. Journal of clinical monitoring and computing. 2016. DOI: 10.1007/s10877-016-9878-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.