MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1365-2710.2004.00609.x

Медицинская библиотека · Journal of clinical pharmacy and therapeutics · 2004

Increased digitalis-like immunoreactive substances in neonatal plasma measured using fluorescence polarization immunoassay.

Ijiri Y, Hayahi T, Ogihara T, Ohi K, Suzuki K, Tamai H, Kitaura Y, Takenaka H, Tanaka K

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To better define the reported increased digitalis-like immunoreactive substances (DLIS) in neonatal plasma, we studied the relation among plasma DLIS level, blank intensity (BLK-I) value at FPIA measurement and plasma total bilirubin level.

METHODS

The DLIS levels were measured in 10 neonates with or without jaundice and 10 infants in good health, using fluorescence polarization immunoassay (FPIA) and microparticle enzyme immunoassay (MEIA). BLK-I value and plasma total bilirubin level were also measured simultaneously.

RESULTS

In neonates with jaundice, DLIS using FPIA, BLK-I and total bilirubin level were 0.58 +/-0.13 ng/mL, 2598 +/- 408, and 17.98 +/- 1.13 mg/dL, respectively, before phototherapy, and 0.33 +/-0.06 ng/mL, 1886 +/- 237, and 15.16 +/- 2.07 mg/dL after phototherapy. Corresponding values in neonates without jaundice were (DLIS: 0.34 +/-0.04 ng/mL; BLK-I: 1,764 +/- 278; total bilirubin: 10.37 +/- 4.54 mg/dL); in healthy infants (0.12 +/-0.06 ng/mL, 400.7 +/- 4.6 and 0.42 +/- 0.13 mg/dL, respectively) and in healthy volunteers (0.10 +/-0.07 ng/mL, 403.1 +/- 8.4, and 0.58 +/- 0.30 mg/dL, respectively). Using MEIA, DLIS was not detected in 10 neonates, 10 infants and 20 healthy volunteers.

CONCLUSIONS

A fluorescent compound related to bilirubin increased the BLK-I value in the measurement of neonatal plasma using FPIA. The fluorescence was not the result of endogenous digitalis-like factors.

Для цитирования: Ijiri Y, Hayahi T, Ogihara T, Ohi K, Suzuki K, Tamai H, Kitaura Y, Takenaka H, Tanaka K. Increased digitalis-like immunoreactive substances in neonatal plasma measured using fluorescence polarization immunoassay.. Journal of clinical pharmacy and therapeutics. 2004. DOI: 10.1111/j.1365-2710.2004.00609.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.