MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00004728-199103000-00002

Медицинская библиотека · Journal of computer assisted tomography · 1991

MR imaging of anisotropically restricted diffusion in the brain of neonates and infants.

Rutherford M A, Cowan F M, Manzur A Y, Dubowitz L M, Pennock J M, Hajnal J V, Young I R, Bydder G M

СтатьяПеревод в очереди

Аннотация

Brain MR examinations were performed on one normal and 30 abnormal neonates and infants with a variety of clinical problems using pulsed gradient spin echo (PGSE) sequences sensitized in different directions to detect changes due to anisotropically restricted diffusion of water within the brain. Anisotropically restricted diffusion was demonstrated within white matter, which appeared to be myelinated with T1-weighted inversion recovery or spin echo sequences and within white matter where the presence of myelin was not demonstrated with these sequences. Cysts and fluid collections were recognised by their low signal intensity using PGSE sequences in the subcortical regions, lentiform nuclei, and periventricular regions. An intracerebral hematoma and a subdural hematoma showed a high signal intensity with PGSE sequences consistent with isotropically restricted diffusion. Chronic infarction displayed a low signal intensity consistent with relatively free isotropic diffusion. Patients with leukodystrophy associated with congenital muscular dystrophy showed an anisotropic pattern with different components of the abnormality present on images with sensitization in different directions. The corticospinal tracts failed to show highlighting in three cases where conventional imaging was normal. In several patients with a history of birth asphyxia, asymmetry and a relative reduction in signal intensity were seen in the corticospinal tracts.

Для цитирования: Rutherford M A, Cowan F M, Manzur A Y, Dubowitz L M, Pennock J M, Hajnal J V, Young I R, Bydder G M. MR imaging of anisotropically restricted diffusion in the brain of neonates and infants.. Journal of computer assisted tomography. 1991. DOI: 10.1097/00004728-199103000-00002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.