Shah Kamal, Wang Anran, Chen Yiwen, Munjal Jitender, Chhabra Sumeet, Stange Anthony, Wei Enxun, Phan Tuan, Giest Tracy, Hawkins Beszel, Puppala Dinesh, Silver Elsina, Cai Lawrence, Rajagopalan Shruti, Shi Edward, Lee Yun-Ling, Wimmer Matt, Rudrapatna Pramod, Rea Thomas, Yuen Shelten, Pathak Anupam, Patel Shwetak, Malhotra Mark, Stogaitis Marc, Phan Jeanie, Patel Bakul, Vasquez Adam, Fox Christina, Connell Alistair, Taylor Jim, Shreibati Jacqueline, Miller David, McDuff Daniel, Kohli Pushmeet, Gadh Tajinder, Sunshine Jake

Аннотация

Out-of-hospital cardiac arrest is a time-sensitive emergency that requires prompt identification and intervention: sudden, unwitnessed cardiac arrest is nearly unsurvivable1-3. A cardinal sign of cardiac arrest is sudden loss of pulse4. Automated biosensor detection of unwitnessed cardiac arrest, and dispatch of medical assistance, may improve survivability given the substantial prognostic role of time3,5, but only if the false-positive burden on public emergency medical systems is minimized5-7. Here we show that a multimodal, machine learning-based algorithm on a smartwatch can reach performance thresholds making it deployable at a societal scale. First, using photoplethysmography, we show that wearable photoplethysmography measurements of peripheral pulselessness (induced through an arterial occlusion model) manifest similarly to pulselessness caused by a common cardiac arrest arrhythmia, ventricular fibrillation. On the basis of the similarity of the photoplethysmography signal (from ventricular fibrillation or arterial occlusion), we developed and validated a loss of pulse detection algorithm using data from peripheral pulselessness and free-living conditions. Following its development, we evaluated the end-to-end algorithm prospectively: there was 1 unintentional emergency call per 21.67 user-years across two prospective studies; the sensitivity was 67.23% (95% confidence interval of 64.32% to 70.05%) in a prospective arterial occlusion cardiac arrest simulation model. These results indicate an opportunity, deployable at scale, for wearable-based detection of sudden loss of pulse while minimizing societal costs of excess false detections7.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты