MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/elps.202000163

Медицинская библиотека · Electrophoresis · 2020

Low-cost and versatile analytical tool with purpose-made capillary electrophoresis coupled to contactless conductivity detection: Application to antibiotics quality control in Vietnam.

Le Thai Binh, Hauser Peter C, Pham Thi Ngoc Mai, Kieu Thi Lan Phuong, Le Thi Phuong Quynh, Hoang Quoc Anh, Le Dinh Chi, Nguyen Thi Anh Huong, Mai Thanh Duc

СтатьяПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод в очереди

Аннотация

In this study, the development of our purpose-made capacitively coupled contactless conductivity detection (C4 D) for CE is reported. These systems have been employed as a simple, versatile, and cost-effective analytical tool. CE-C4 D devices, whose principle is based on the control of the ion movements under an electrical field, can be constructed even with a modest financial budget and limited infrastructure. A featured application was developed for quality control of antimicrobial drugs using CE-C4 D, with most recent work on determination of aminoglycoside and glycopeptide antibiotics being communicated. For aminoglycosides, the development of CE-C4 D methods was adapted to two categories. The first one includes drugs (liquid or powder form) for intravenous injection, containing either amikacin, streptomycin, kanamycin A, or kanamycin B. The second one covers drugs for eye drops (liquid or ointment form), containing either neomycin, tobramycin, or polymyxin. The CE-C4 D method development was also made for determination of some popular glycopeptide antibiotics in Vietnam, including vancomycin and teicoplanin. The best detection limit achieved using the developed CE-C4 D methods was 0.5 mg/L. Good agreement between results from CE-C4 D and the confirmation method (HPLC- Photometric Diode Array ) was achieved, with their result deviations less than 8% and 13% for aminoglycoside and glycopeptide antibiotics, respectively.

Для цитирования: Le Thai Binh, Hauser Peter C, Pham Thi Ngoc Mai, Kieu Thi Lan Phuong, Le Thi Phuong Quynh, Hoang Quoc Anh, Le Dinh Chi, Nguyen Thi Anh Huong, Mai Thanh Duc. Low-cost and versatile analytical tool with purpose-made capillary electrophoresis coupled to contactless conductivity detection: Application to antibiotics quality control in Vietnam.. Electrophoresis. 2020. DOI: 10.1002/elps.202000163.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.