MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3233/thc-220361

Медицинская библиотека · Technology and health care : official journal of the European Society for Engineering and Medicine · 2023

Exploring the relationship between brain white matter change and higher degree of invisible hand tremor with computer technology.

Hu Yang, Wu Yanqing, Tu Jianglong, Su Hai, Zeng Luchuan, Lei Jie, Xia Linglin

СтатьяПеревод в очереди

Аннотация

BACKGROUND

At present, the clinical diagnosis of white matter change (WMC) patients depends on cranial magnetic resonance imaging (MRI) technology. This diagnostic method is costly and does not allow for large-scale screening, leading to delays in the patient's condition due to inability to receive timely diagnosis.

OBJECTIVE

To evaluate whether the burden of WMC is associated with the degree of invisible hand tremor in humans.

METHODS

Previous studies have shown that tremor is associated with WMC, however, tremor does not always have imaging of WMC. Therefore, to confirm that the appearance of WMC causes tremor, which are sometimes invisible to the naked eye, we achieved an optical-based computer-aided diagnostic device by detecting the invisible hand tremor, and we proposed a calculation method of WMC volume by using the characteristics of MRI images.

RESULTS

Statistical analysis results further clarified the relationship between WMC and tremor, and our devices are validated for the detection of tremors with WMC.

CONCLUSIONS

The burden of WMC volume is positive factor for degree of invisible hand tremor in the participants without visible hand tremor. Detection technology provides a more convenient and low-cost evaluating method before MRI for tremor diseases.

Для цитирования: Hu Yang, Wu Yanqing, Tu Jianglong, Su Hai, Zeng Luchuan, Lei Jie, Xia Linglin. Exploring the relationship between brain white matter change and higher degree of invisible hand tremor with computer technology.. Technology and health care : official journal of the European Society for Engineering and Medicine. 2023. DOI: 10.3233/thc-220361.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.