MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0196617

Медицинская библиотека · PloS one · 2018

Optimized application of the secreted Nano-luciferase reporter system using an affinity purification strategy.

Li JingZhe, Guo ZhiLan, Sato Takashi, Yuan Bo, Ma YanYan, Qian Dan, Zhong JuYing, Jin MengMeng, Huang Peng, Che LuYang, Wang Yi, Lei Yan, Liu ChangZhen

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Secreted Nano-luciferase (secNluc) is a newly engineered secreted luciferase that possesses advantages of high structural stability, long half-life, and glow-type kinetics together with high light emission intensity, and thus would become one of the most valuable tools for bioluminescence assays. However, like other secreted luciferases, secNluc has to mix with the components in the conditioned medium surrounding test cells, or in the biological samples such as blood or urine after being secreted. These components may interfere with secNluc-catalyzed bioluminescence reactions and thus limit the application of the secNluc reporter system. In this study, we first examined the effects of three factors, pH, serum and residual reagents, on secNluc-catalyzed bioluminescence reactions, finding that these factors could interfere with bioluminescence reactions and result in background signal. To resolve these problems, we applied a simple affinity purification strategy in which secNluc was fused with a FLAG-tag, and anti-FLAG magnetic beads were used to catch and transfer the fusion protein to PBST, an optimal buffer for secNluc-catalyzed bioluminescence reactions that was identified in this study. The results indicated that this strategy could not only negate the interferences from serum or residual reagents and enhance the stability of light emission but also greatly increase signal intensity through enzyme enrichment. This strategy may contribute to biomedical studies that utilize secNluc and other secreted luciferases, especially those requiring superior sensitivity, low background noise and high reproducibility.

Для цитирования: Li JingZhe, Guo ZhiLan, Sato Takashi, Yuan Bo, Ma YanYan, Qian Dan, Zhong JuYing, Jin MengMeng, Huang Peng, Che LuYang, Wang Yi, Lei Yan, Liu ChangZhen. Optimized application of the secreted Nano-luciferase reporter system using an affinity purification strategy.. PloS one. 2018. DOI: 10.1371/journal.pone.0196617.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.