MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/j.jfas.2013.12.007

Медицинская библиотека · The Journal of foot and ankle surgery : official publication of the American College of Foot and Ankle Surgeons · 2014

Button fixation technique for Achilles tendon reinsertion: a biomechanical study.

Awogni David, Chauvette Guillaume, Lemieux Marie-Line, Balg Frédéric, Langelier Ève, Allard Jean-Pascal

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Chronic insertional tendinopathy of the Achilles tendon is a frequent and disabling pathologic entity. Operative treatment is indicated for patients for whom nonoperative management has failed. The treatment can consist of the complete detachment of the tendon insertion and extensive debridement. We biomechanically tested a new operative technique that uses buttons for fixation of the Achilles tendon insertion on the posterior calcaneal tuberosity and compared it with 2 standard bone anchor techniques. A total of 40 fresh-frozen cadaver specimens were used to compare 3 fixation techniques for reinserting the Achilles tendon: single row anchors, double row anchors, and buttons. The ultimate loads and failure mechanisms were recorded. The button assembly (median load 764 N, range 713 to 888) yielded a median fixation strength equal to 202% (range 137% to 251%) of that obtained with the double row anchors (median load 412 N, range 301 to 571) and 255% (range 213% to 317%) of that obtained with the single row anchors (median load 338 N, range 241 to 433N). The most common failure mechanisms were suture breakage with the buttons (55%) and pull out of the implant with the double row (70%) and single row (85%) anchors. The results of the present biomechanical cadaver study have shown that Achilles tendon reinsertion fixation using the button technique provides superior pull out strength than the bone anchors tested.

Для цитирования: Awogni David, Chauvette Guillaume, Lemieux Marie-Line, Balg Frédéric, Langelier Ève, Allard Jean-Pascal. Button fixation technique for Achilles tendon reinsertion: a biomechanical study.. The Journal of foot and ankle surgery : official publication of the American College of Foot and Ankle Surgeons. 2014. DOI: 10.1053/j.jfas.2013.12.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.