MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5665/sleep.4578

Медицинская библиотека · Sleep · 2015

Detection of upper airway status and respiratory events by a current generation positive airway pressure device.

Li Qing Yun, Berry Richard B, Goetting Mark G, Staley Bethany, Soto-Calderon Haideliza, Tsai Sheila C, Jasko Jeffrey G, Pack Allan I, Kuna Samuel T

Клиническое исследованиеСтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

STUDY

OBJECTIVES

To compare a positive airway pressure (PAP) device's detection of respiratory events and airway status during device-detected apneas with events scored on simultaneous polysomnography (PSG).

DESIGN

Prospective PSGs of patients with sleep apnea using a new-generation PAP device.

SETTINGS: Four clinical and academic sleep centers.

PATIENTS: Forty-five patients with obstructive sleep apnea (OSA) and complex sleep apnea (Comp SA) performed a PSG on PAP levels adjusted to induce respiratory events.

INTERVENTIONS: None.

MEASUREMENTS AND

RESULTS

PAP device data identifying the type of respiratory event and whether the airway during a device-detected apnea was open or obstructed were compared to time-synced, manually scored respiratory events on simultaneous PSG recording. Intraclass correlation coefficients between device-detected and PSG scored events were 0.854 for apnea-hypopnea index (AHI), 0.783 for apnea index, 0.252 for hypopnea index, and 0.098 for respiratory event-related arousals index. At a device AHI (AHIFlow) of 10 events/h, area under the receiver operating characteristic curve was 0.98, with sensitivity 0.92 and specificity 0.84. AHIFlow tended to overestimate AHI on PSG at values less than 10 events/h. The device detected that the airway was obstructed in 87.4% of manually scored obstructive apneas. Of the device-detected apneas with clear airway, a minority (15.8%) were manually scored as obstructive apneas.

CONCLUSIONS

A device-detected apnea-hypopnea index (AHIFlow) < 10 events/h on a positive airway pressure device is strong evidence of good treatment efficacy. Device-detected airway status agrees closely with the presumed airway status during polysomnography scored events, but should not be equated with a specific type of respiratory event.

Для цитирования: Li Qing Yun, Berry Richard B, Goetting Mark G, Staley Bethany, Soto-Calderon Haideliza, Tsai Sheila C, Jasko Jeffrey G, Pack Allan I, Kuna Samuel T. Detection of upper airway status and respiratory events by a current generation positive airway pressure device.. Sleep. 2015. DOI: 10.5665/sleep.4578.