Falsely elevated intraocular pressure due to an abnormally thick cornea in a patient with nevus of Ota.

Kitagawa Kiyotaka, Hayasaka Seiji, Nagaki Yasunori

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Several ocular complications, including glaucoma and ocular hypertension, have been reported in patients with nevus of Ota.

CASE: A 12-year-old boy with nevus of Ota on the left side of his face was referred for further examination of elevated intraocular pressure in his left eye.

OBSERVATIONS: Intraocular pressure measured with Goldmann tonometry was 19 mm Hg OD and 25 mm Hg OS. No visual field defects were detected by Goldmann or Humphrey perimetry. With ultrasonic pachymetry, the mean +/- SD of central corneal thickness was 560 +/- 4 microm in the right eye and 652 +/- 9 microm in the left.

CONCLUSION

Ophthalmologists should be aware that the abnormally thick cornea of patients with nevus of Ota may produce falsely elevated intraocular pressure readings.

Для цитирования: Kitagawa Kiyotaka, Hayasaka Seiji, Nagaki Yasunori. Falsely elevated intraocular pressure due to an abnormally thick cornea in a patient with nevus of Ota.. Japanese journal of ophthalmology. 2003. DOI: 10.1016/s0021-5155(02)00703-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.