m+Medelevator.RU
← Поиск публикаций
Journal of sleep research · 2018

Ability of the Fitbit Alta HR to quantify and classify sleep in patients with suspected central disorders of hypersomnolence: A comparison against polysomnography.

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Cook Jesse D, Eftekari Sahand C, Dallmann Erika, Sippy Megan, Plante David T

Аннотация

Measuring sleep duration and early onset rapid eye movement sleep (REMS) is critical in the assessment of suspected central disorders of hypersomnolence (CDH). Current multi-sensor activity trackers that integrate accelerometry and heart rate are purported to accurately quantify sleep time and REMS; however, their utility in suspected CDH has not been established. This investigation aimed to determine the ability of a current, multi-sensor tracker, Fitbit Alta HR (FBA-HR), to quantify and classify sleep in patients with suspected CDH relative to polysomnography (PSG). Forty-nine patients (46 female; mean age, 30.3 ± 9.84 years) underwent ad libitum PSG with concurrent use of the FBA-HR. FBA-HR sleep variable quantification was assessed using Bland-Altman analysis. FBA-HR all sleep (AS), light sleep (LS; PSG N1 + N2), deep sleep (DS; PSG N3) and REMS classification was evaluated using epoch-by-epoch comparisons. FBA-HR-detected sleep-onset rapid eye movement periods (SOREMPs) were compared against PSG SOMREMPs. FBA-HR displayed significant overestimation of total sleep time (11.6 min), sleep efficiency (1.98%) and duration of deep sleep (18.2 min). FBA-HR sensitivity and specificity were as follows: AS, 0.96, 0.58; LS, 0.73, 0.72;DS, 0.67, 0.92; REMS, 0.74, 0.93. The device failed to detect any nocturnal SOREMPs. Device performance did not differ appreciably among diagnostic subgroups. These results suggest FBA-HR cannot replace EEG-based measurements of sleep and wake in the diagnostic assessment of suspected CDH, and that improvements in device performance are required prior to adoption in clinical or research settings.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты