Pan Xiangbin, Ouyang Wenbin, Li Shoujun, Guo Gaili, Liu Yao, Zhang Dawei, Zhang Fengwen, Pang Kunjing, Fang Nengxin, Hu Shengshou
Аннотация
OBJECTIVE: To avoid the radiation injuries and use of contrast agent, we assessed the safety and efficacy of percutaneous patent ductus arteriosus closure solely under thoracic echocardiography guidance.
METHODS: From June 2013 to June 2014, thirty patients (mean age: (6.3 ± 2.5) years, mean body weight:(22.5 ± 7.3) kg) with pure patent ductus arteriosus were continuously included in this study. The mean diameter of patent ductus arteriosus was (3.8 ± 0.9) mm. Patients were all treated by percutaneous patent ductus arteriosus closure via right femoral artery solely under thoracic echocardiography guidance. The efficacy of the procedure was evaluated by thoracic echocardiography. Follow-up was performed at one month after procedure.
RESULTS: All 30 cases were successfully treated with percutaneous patent ductus arteriosus closure solely under thracic echocardiography guidance. The procedural time was (32.8 ± 5.7) minutes. The mean diameter of Amplatzer ADO II was (4.9 ± 1.0) mm. Postoperative trivial residual shunt occurred in six patients immediately after the procedure. All patients survived without peripheral vascular injury or complications such as cardiac perforation. Hospitalization time was (3.4 ± 0.7) days. At one-month follow-up, no complications such as residual shunt or pericardial effusion were observed.
CONCLUSION: Echocardiography guided percutaneous patent ductus arteriosus closure by femoral artery approach is safe and effective, and can avoid X-ray and the use of contrast agents.
METHODS: From June 2013 to June 2014, thirty patients (mean age: (6.3 ± 2.5) years, mean body weight:(22.5 ± 7.3) kg) with pure patent ductus arteriosus were continuously included in this study. The mean diameter of patent ductus arteriosus was (3.8 ± 0.9) mm. Patients were all treated by percutaneous patent ductus arteriosus closure via right femoral artery solely under thoracic echocardiography guidance. The efficacy of the procedure was evaluated by thoracic echocardiography. Follow-up was performed at one month after procedure.
RESULTS: All 30 cases were successfully treated with percutaneous patent ductus arteriosus closure solely under thracic echocardiography guidance. The procedural time was (32.8 ± 5.7) minutes. The mean diameter of Amplatzer ADO II was (4.9 ± 1.0) mm. Postoperative trivial residual shunt occurred in six patients immediately after the procedure. All patients survived without peripheral vascular injury or complications such as cardiac perforation. Hospitalization time was (3.4 ± 0.7) days. At one-month follow-up, no complications such as residual shunt or pericardial effusion were observed.
CONCLUSION: Echocardiography guided percutaneous patent ductus arteriosus closure by femoral artery approach is safe and effective, and can avoid X-ray and the use of contrast agents.