MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ab.2018.02.010

Медицинская библиотека · Analytical biochemistry · 2018

RPA using a multiplexed cartridge for low cost point of care diagnostics in the field.

Ereku Luck Tosan, Mackay Ruth E, Craw Pascal, Naveenathayalan Angel, Stead Thomas, Branavan Manorharanehru, Balachandran Wamadeva

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A point of care device utilising Lab-on-a-Chip technologies that is applicable for biological pathogens was designed, fabricated and tested showing sample in to answer out capabilities. The purpose of the design was to develop a cartridge with the capability to perform nucleic acid extraction and purification from a sample using a chitosan membrane at an acidic pH. Waste was stored within the cartridge with the use of sodium polyacrylate to solidify or gelate the sample in a single chamber. Nucleic acid elution was conducted using the RPA amplification reagents (alkaline pH). Passive valves were used to regulate the fluid flow and a multiplexer was designed to distribute the fluid into six microchambers for amplification reactions. Cartridges were produced using soft lithography of silicone from 3D printed moulds, bonded to glass substrates. The isothermal technique, RPA is employed for amplification. This paper shows the results from two separate experiments: the first using the RPA control nucleic acid, the second showing successful amplification from Chlamydia Trachomatis. Endpoint analysis conducted for the RPA analysis was gel electrophoresis that showed 143 base pair DNA was amplified successfully for positive samples whilst negative samples did not show amplification. End point analysis for Chlamydia Trachomatis samples was fluorescence detection that showed successful detection of 1 copy/μL and 10 copies/μL spiked in a MES buffer.

Для цитирования: Ereku Luck Tosan, Mackay Ruth E, Craw Pascal, Naveenathayalan Angel, Stead Thomas, Branavan Manorharanehru, Balachandran Wamadeva. RPA using a multiplexed cartridge for low cost point of care diagnostics in the field.. Analytical biochemistry. 2018. DOI: 10.1016/j.ab.2018.02.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.