Anyplex II HPV28 detection and Anyplex II HPV HR detection assays are highly concordant with other commercial assays for detection of high-risk HPV genotypes in women with high grade cervical abnormalities.

Сравнительное исследованиеОценочное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Cornall A M, Poljak M, Garland S M, Phillips S, Tan J H, Machalek D A, Quinn M A, Tabrizi S N

Аннотация

PURPOSE: to evaluate the performance of Anyplex II HPV28 and HPV HR Detection assays against the EuroArray HPV, Cobas 4800 HPV (Cobas), HPV Amplicor (Amp), Linear Array HPV (LA) and Hybrid Capture 2 (HC2) in detection of high-risk HPV (HR-HPV) from liquid-based cervical cytology samples.

METHODS: cervical specimens from 404 women undergoing management of high-grade cytological abnormality were evaluated by Anyplex II HPV28 and HPV HR Detection assays for detection of HR-HPV genotypes and prediction of histologically-confirmed cervical intraepithelial neoplasia grade 2 or higher (≥CIN2). The results were compared to EuroArray, HC2, Cobas, Amp, and LA.

RESULTS: specimens were evaluated from 404 women with an average age of 30 years, including 336 with a histological diagnosis of ≥ CIN2 and 68 with ≤ CIN1. Concordance of HR-HPV detection between Anyplex II HPV28 and other genotyping assays was 94.79 % (κ = 0.84; EuroArray) and 97.27 % (κ = 0.91; LA); and between Anyplex II HPV HR and other HR-HPV detection assays was 86.35 % (κ = 0.62; HC2), 96.03 % (κ = 0.87; Cobas) and 96.77 % (κ = 0.89; Amp). Using HR-HPV detection for prediction of ≥ CIN2 by Anyplex II HPV28 and HPV HR, sensitivity (90.18, 95 % CI 86.48-93.14; 90.77, 95 % CI 87.16-93.65) and specificity (both 67.16, 95 % CI 54.60-78.15) were not significantly different to the other HPV assays tested, with one exception. Both Anyplex assays had significantly higher sensitivity than HC2 (p < 0.0001), with a specificity of 96 % (p > 0.05) of HC2 in this high-risk population.

CONCLUSIONS: both Anyplex II HPV detection assays were concordant with other commercial assays for HR-HPV detection, with comparable sensitivity and specificity for ≥ CIN2 detection.