MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.diagmicrobio.2017.03.010

Медицинская библиотека · Diagnostic microbiology and infectious disease · 2017

Clinical evaluation of a new single-tube multiplex reverse transcription PCR assay for simultaneous detection of 11 respiratory viruses, Mycoplasma pneumoniae and Chlamydia in hospitalized children with acute respiratory infections.

Zhao Meng-Chuan, Li Gui-Xia, Zhang Dan, Zhou Hang-Yu, Wang Hao, Yang Shuo, Wang Le, Feng Zhi-Shan, Ma Xue-Jun

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод в очереди

Аннотация

Respiratory Pathogen 13 Detection Kit (13× kit) is able to simultaneously detect 11 respiratory viruses, Mycoplasma pneumoniae (MP) and Chlamydia in a single reaction. Using 572 Nasopharyngeal aspirates collected from hospitalized children, the clinical performance of 13× kit for detecting 11 respiratory viruses was evaluated in comparison with a routinely used 2-tube multiplex reverse transcription PCR assay (2-tube assay) at provincial Centers for Disease Control and Prevention in China. The clinical performance of 13× kit for detecting MP and Chlamydia was evaluated by commercial real-time quantitative PCR (qPCR) kits or sequencing. For tested viruses, the assay concordance was 95.98% and the kappa coefficient was 0.89. All the MP and Chlamydia positive samples detected by 13× kit were confirmed as true positives. The utilization of the 13× kit in clinical settings will be helpful for doctors to assess clinical outcome according to virus type or multiple infections, and to limit the use of antibiotics.

Для цитирования: Zhao Meng-Chuan, Li Gui-Xia, Zhang Dan, Zhou Hang-Yu, Wang Hao, Yang Shuo, Wang Le, Feng Zhi-Shan, Ma Xue-Jun. Clinical evaluation of a new single-tube multiplex reverse transcription PCR assay for simultaneous detection of 11 respiratory viruses, Mycoplasma pneumoniae and Chlamydia in hospitalized children with acute respiratory infections.. Diagnostic microbiology and infectious disease. 2017. DOI: 10.1016/j.diagmicrobio.2017.03.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.