MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Zhonghua yi xue yi chuan xue za zhi = Zhonghua yixue yichuanxue zazhi = Chinese journal of medical genetics · 2004

[Mutation detection of PKD2 gene in Chinese by denaturing high-performance liquid chromatograph].

Zhang Dian-yong, Sun Tian-mei, Zhang Shu-zhong, Tang Bing, Dai Bing, Zhang Wei-li, Mei Chang-lin

Аннотация на английскомСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To detect the mutations of autosomal dominant polycystic kidney disease gene 2(PKD2)in Chinese.

METHODS

The white blood cell genomic DNA from patients of 94 Chinese autosomal dominant polycystic kidney disease(ADPKD) pedigrees was isolated and amplified by polymerase chain reaction(PCR). The PCR products were analyzed by denaturing high-performance liquid chromatography(DHPLC). The samples with abnormal profiles were sequenced.

RESULTS

Eight mutations were identified, including 2 nonsense mutations, 2 deletion mutations,1 insertion mutation and 3 missense mutations. Two nonsense mutations occurred in exon 5(1249C-->T) and exon 13(2407C-->T),both resulted in a stop codon. The insertion was in exon 2(636-637 ins T),and the deletion mutations were in exons 12(2348-2351 del AGAA) and 13(2401 delete A),resulting in the reading frame shift. Three missense mutations were in exons 1(G568-->A),4(C964-->T),and 5(G1168-->A), which caused amino acid changes (190Ala-->Thr,322Arg-->Trp,390Gly-->Ser).

CONCLUSION

The method of DHPLC was used in detecting mutations successfully and 8 mutations in PKD2 were identified. It will be useful in the molecular diagnosis of ADPKD in advance of the cysts formation and birth.

Для цитирования: Zhang Dian-yong, Sun Tian-mei, Zhang Shu-zhong, Tang Bing, Dai Bing, Zhang Wei-li, Mei Chang-lin. [Mutation detection of PKD2 gene in Chinese by denaturing high-performance liquid chromatograph].. Zhonghua yi xue yi chuan xue za zhi = Zhonghua yixue yichuanxue zazhi = Chinese journal of medical genetics. 2004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.