MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.chroma.2024.465095

Медицинская библиотека · Journal of chromatography. A · 2024

Determination of low carbon aldehydes and ketones in cigarette smoke by MXene membrane enrichment-liquid chromatography.

Xu Xin, Wang Wenjing, Zheng Feng, Zhang Tao, Li Chun-Lai, Abulaiti Tuerhongjiang, Pan Xiao, Zhao Ying, Zeng Jingbin

СтатьяПеревод в очереди

Аннотация

Low carbon aldehydes and ketones are typical substances harmful to human body produced during cigarette smoking. Their contents in cigarette smoke are important indicators for evaluating its toxicity and the filtration effect of cigarette filter tips, which provides important guidance for its rational design. In this work, MXene membrane with unique lamellar structure was synthesized and loaded onto glass fiber filters to achieve effective enrichment of low carbon aldehydes and ketones. Compared to commercial Cambridge filters, the MXene-loaded filters exhibited higher extraction efficiency towards low-carbon aldehydes and ketones, making viable the detection of butyraldehyde, which was not detected by that enriched with Cambridge filters. Therefore, a MXene-based membrane enrichment-HPLC method was developed for the determination of low-carbon aldehydes and ketones in cigarette smoke with detection limits ranging from 0.133 μg/mL to 0.285 μg/mL. The applicability of the method was verified by analyzing three different types of filter cigarettes with the concentration in the range of 0.5-140 μg/branch for all the analytes, which were in good agreement with the manufacturer's results. The method is accurate and sensitive, and can be used for the quantitative determination of low carbon aldehydes and ketones in cigarette smoke.

Для цитирования: Xu Xin, Wang Wenjing, Zheng Feng, Zhang Tao, Li Chun-Lai, Abulaiti Tuerhongjiang, Pan Xiao, Zhao Ying, Zeng Jingbin. Determination of low carbon aldehydes and ketones in cigarette smoke by MXene membrane enrichment-liquid chromatography.. Journal of chromatography. A. 2024. DOI: 10.1016/j.chroma.2024.465095.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.