MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/tbme.2022.3233345

Медицинская библиотека · IEEE transactions on bio-medical engineering · 2023

Low-Intensity Pulsed Ultrasound Neuromodulation of a Rodent's Spinal Cord Suppresses Motor Evoked Potentials.

Tsehay Yohannes, Zeng Yinuo, Weber-Levine Carly, Awosika Tolulope, Kerensky Max, Hersh Andrew M, Ou Ze, Jiang Kelly, Bhimreddy Meghana, Bauer Stuart J, Theodore John N, Quiroz Victor M, Suk Ian, Alomari Safwan, Sun Junfeng, Tong Shanbao, Thakor Nitish, Doloff Joshua C, Theodore Nicholas, Manbachi Amir

СтатьяПоддержка исследования: вне правительства СШАПоддержка NIH: внешняя программаПоддержка правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

Here we investigate the ability of low-intensity ultrasound (LIUS) applied to the spinal cord to modulate the transmission of motor signals.

METHODS

Male adult Sprague-Dawley rats (n = 10, 250-300 g, 15 weeks old) were used in this study. Anesthesia was initially induced with 2% isoflurane carried by oxygen at 4 L/min via a nose cone. Cranial, upper extremity, and lower extremity electrodes were placed. A thoracic laminectomy was performed to expose the spinal cord at the T11 and T12 vertebral levels. A LIUS transducer was coupled to the exposed spinal cord, and motor evoked potentials (MEPs) were acquired each minute for either 5- or 10-minutes of sonication. Following the sonication period, the ultrasound was turned off and post-sonication MEPs were acquired for an additional 5 minutes.

RESULTS

Hindlimb MEP amplitude significantly decreased during sonication in both the 5- (p < 0.001) and 10-min (p = 0.004) cohorts with a corresponding gradual recovery to baseline. Forelimb MEP amplitude did not demonstrate any statistically significant changes during sonication in either the 5- (p = 0.46) or 10-min (p = 0.80) trials.

CONCLUSION

LIUS applied to the spinal cord suppresses MEP signals caudal to the site of sonication, with recovery of MEPs to baseline after sonication.

SIGNIFICANCE: LIUS can suppress motor signals in the spinal cord and may be useful in treating movement disorders driven by excessive excitation of spinal neurons.

Для цитирования: Tsehay Yohannes, Zeng Yinuo, Weber-Levine Carly, Awosika Tolulope, Kerensky Max, Hersh Andrew M, Ou Ze, Jiang Kelly, Bhimreddy Meghana, Bauer Stuart J, Theodore John N, Quiroz Victor M, Suk Ian, Alomari Safwan, Sun Junfeng, Tong Shanbao, Thakor Nitish, Doloff Joshua C, Theodore Nicholas, Manbachi Amir. Low-Intensity Pulsed Ultrasound Neuromodulation of a Rodent's Spinal Cord Suppresses Motor Evoked Potentials.. IEEE transactions on bio-medical engineering. 2023. DOI: 10.1109/tbme.2022.3233345.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.