MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/hjh.0000000000003018

Медицинская библиотека · Journal of hypertension · 2022

Urine N-acetyl-Ser-Asp-Lys-Pro measurement as a versatile biomarker to assess adherence to angiotensin-converting enzyme inhibitors.

Kably Benjamin, Billaud Eliane M, Derobertmasure Audrey, Blanchard Anne, Boutouyrie Pierre, Azizi Michel

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Poor adherence to treatment is a major health issue in hypertension. The large number of drugs to be detected limits the implementation of chemical adherence testing by liquid chromatography/mass spectrometry (LC-MS/MS). AcSDKP, a peptide accumulating in the presence of angiotensin-converting-enzyme inhibitor (ACEI) treatment, has been validated as a proven marker of adherence by enzyme-linked immunosorbent assay. Our aim was to validate urine measurements of AcSDKP compared with active metabolites of various ACEI, measured simultaneously by LC-MS/MS.

METHOD: We first studied the time-dependent relationships between urinary perindoprilat and AcSDKP in a pharmacokinetic/pharmacodynamic study in healthy volunteers. We then compared the sensitivity and specificity of urinary AcSDKP vs. three ACEI active metabolites (enalaprilat, perindoprilat, ramiprilat) taken as reference to detect nonadherence in spot urine samples from a prospective cohort of hypertensive outpatients.

RESULTS

The urinary excretion profiles of AcSDKP and perindoprilat were similar, exhibited a significant correlation, and showed excellent agreement in healthy volunteers. In patients, we found a similar agreement between AcSDKP and the three ACEI metabolites urinary concentrations. The sensitivity and specificity for adherence assessment of urine AcSDKP was 92.2 and 100%, respectively. We observed a difference in the evaluation of good adherence between ACEI metabolites (85.7%) and AcSDKP (79.0%) because of discrepancies in samples where AcSDKP reached undetectability quicker than ACEI metabolites. This characteristic of AcSDKP is of particular interest and could better reflect the true adherence status of patients.

CONCLUSION

Overall, spot urine AcSDKP measurement by LC-MS/MS is a reliable marker of the intake of ACEI treatment and could substitute ACEI metabolites detection.

Для цитирования: Kably Benjamin, Billaud Eliane M, Derobertmasure Audrey, Blanchard Anne, Boutouyrie Pierre, Azizi Michel. Urine N-acetyl-Ser-Asp-Lys-Pro measurement as a versatile biomarker to assess adherence to angiotensin-converting enzyme inhibitors.. Journal of hypertension. 2022. DOI: 10.1097/hjh.0000000000003018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.