3-T MRI of the shoulder: is MR arthrography necessary?
Аннотация
OBJECTIVE
The purpose of this study is to report the diagnostic sensitivity of 3-T conventional MRI versus MR arthrography of the shoulder in the same patient population.
MATERIALS AND
METHODS
One hundred fifty consecutive conventional shoulder MRI and MR arthrography examinations performed on patients 50 years or younger who subsequently underwent arthroscopy were reviewed retrospectively by consensus reading by two musculoskeletal radiologists. All patients selected for arthroscopy had abnormal findings on clinical examination and MRI or MR arthrography. All 150 patients were referred from one orthopedic group. All patients consented to undergo both MRI and MR arthrography. None had undergone prior shoulder surgery. Full- or partial-thickness supraspinatus tendon tears, superior labral anterior-to-posterior (SLAP) tears, and anterior or posterior labral tears were assessed.
RESULTS
Three full-thickness and nine partial-thickness supraspinatus tendon tears, seven SLAP tears, six anterior labral tears, and two posterior labral tears were seen on MR arthrography but not on conventional MRI. All additional MR arthrography findings were confirmed at arthroscopy. On conventional MRI, sensitivities and specificities compared with arthroscopy were as follows: anterior labral tear, 83% sensitivity and 100% specificity; posterior labral tear, 84% and 100%; SLAP tear, 83% and 99%; supraspinatus tendon tear, 92% and 100%; partial-thickness articular surface tear, 68% and 100%; and partial-thickness bursal surface tear, 84% and 100%. On MR arthrography, sensitivities and specificities compared with arthroscopy were as follows: anterior labral tear, 98% sensitivity and 100% specificity; posterior labral tear, 95% and 100%; SLAP tear, 98% and 99%; supraspinatus tendon tear, 100% and 100%; partial-thickness articular surface tear, 97% and 100%; and partial-thickness bursal surface tear, 84% and 100%. MR arthrography showed a statistical improvement in sensitivity (p<0.05) for detection of partial-thickness articular surface supraspinatus tears, anterior labral tears, and SLAP tears at 3 T.
CONCLUSION
In this series, MR arthrography showed statistically significant increased sensitivity for detection of partial-thickness articular surface supraspinatus tears, anterior labral tears, and SLAP tears compared with conventional MRI at 3 T. On the basis of the above findings, we perform 3-T MR arthrography on patients for whom anterior labral tears, SLAP tears, and partial-thickness supraspinatus tendon tears are suspected clinically.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.