MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12938-015-0031-7

Медицинская библиотека · Biomedical engineering online · 2015

Wound perimeter, area, and volume measurement based on laser 3D and color acquisition.

Pavlovčič Urban, Diaci Janez, Možina Janez, Jezeršek Matija

СтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Wound measuring serves medical personnel as a tool to assess the effectiveness of a therapy and predict its outcome. Clinically used methods vary from measuring using rules and calipers to sophisticated methods, based on 3D measuring. Our method combines the added value of 3D measuring and well-known segmentation algorithms to enable volume calculation and achieve reliable and operator-independent analysis, as we demonstrate in the paper.

METHODS

Developed 3D measuring system is based on laser triangulation with simultaneous color acquisition. Wound shape analysis is based on the edge-determination, virtual healthy skin approximation over the wound and perimeter, area, and volume calculation. In order to validate the approach, eight operators analyzed four different wounds using proposed method. Measuring bias was assessed by comparing measured values with expected values on an artificially modeled set of wounds.

RESULTS

Results indicate that the perimeter, area, and volume are measured with a repeatability of 2.5 mm, 12 mm(2), and 30 mm(3), respectively, and with a measuring bias of -0.2 mm, -8.6 mm(2), 24 mm(3), respectively.

CONCLUSIONS

According to the results of verification and the fact that typical wound analysis takes 20 seconds, the method for wound shape measurement can be clinically used as a precise tool for objectively monitoring the wound healing based on measuring its 3D shape and color.

Для цитирования: Pavlovčič Urban, Diaci Janez, Možina Janez, Jezeršek Matija. Wound perimeter, area, and volume measurement based on laser 3D and color acquisition.. Biomedical engineering online. 2015. DOI: 10.1186/s12938-015-0031-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.