MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clinph.2005.07.019

Медицинская библиотека · Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology · 2005

Lower frequency variability in the alpha activity in EEG among patients with epilepsy.

Larsson Pål G, Kostov H

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Clinically, intra-subject variability of the alpha frequency is well known, but sparsely documented and practically not used in the evaluation of the electroencephalogram (EEG). In cognitive science, however, the peak alpha frequency (PAF) variations are implemented. The aim of the present study was to document the clinical notion of differences in alpha frequency variations in patients with epilepsy compared to a control group.

METHODS

Standard EEG recordings from 28 patients, 18 with epilepsy and 10 patients having EEG for other reasons were included. Ten seconds of artifact free EEG were sampled from F3, F4, T5, T6, O1 and O2 at the beginning, after hyperventilation and at the end of a 20 m recording and Fast Fourier transforms was applied to these epochs of each recording.

RESULTS

The study showed a lower frequency in the epilepsy group (frontal 9.22 vs. 10.24 Hz, temporal 9.18 vs. 9.88 Hz and occipital 9.42 vs. 10.30 Hz) and lower frequency variability, with lower values in the epilepsy group in occipital (0.8 vs. 1.44 Hz) and temporal leads (0.89 vs. 1.39 Hz). Frontally, the variability was not significant (0.71 vs. 1.18 Hz, P = 0.0824). Within the groups, there was no relation between frequency and variability.

CONCLUSIONS

This study shows that there is PAF variability in the alpha activity. This variability is compromised in patients with epilepsy. Lower alpha frequency is observed in epilepsy group. It is to some extent due to antiepileptic drugs. The lower alpha frequency variability is probably due to a different mechanism as there is no relation between the frequency and its variability within the two groups.

SIGNIFICANCE: The alpha activity shows physiological frequency variations that may be compromised by epilepsy.

Для цитирования: Larsson Pål G, Kostov H. Lower frequency variability in the alpha activity in EEG among patients with epilepsy.. Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology. 2005. DOI: 10.1016/j.clinph.2005.07.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.