MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1468-1331.2012.03875.x

Медицинская библиотека · European journal of neurology · 2012

I123-FP-CIT single-photon emission tomography in patients with long-standing mixed tremor.

de Verdal M, Renard D, Collombier L, Boudousq V, Kotzki P O, Labauge P, Castelnovo G

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: Essential tremor is an abnormal movement characterized by postural and/or kinetic tremor. In some essential tremor patients, rest tremor (RT) is observed but it is not clear if this RT is a feature of essential tremor or a symptom of Parkinson's disease (PD). I123-FP-CIT single-photon emission tomography is used to distinguish essential tremor and PD.

OBJECTIVES

To analyse I123-FP-CIT single-photon emission tomography in a larger series of patients with mixed tremor (i.e. action tremor associated with RT) without PD criteria.

METHODS

We studied 33 consecutives patients (18 men and 15 women) with mixed tremor, clinically and by neuroimaging in all cases.

RESULTS

I123-FP-CIT single-photon emission tomography was abnormal in 25 of our patients (75.7%) with mixed tremor, and we noted a reduced uptake mostly in the putamen. In our patients with abnormal imaging, RT was unilateral in 52%. In 15 of these 25 patients, putaminal reduced uptake was bilateral and symmetrical. In the other 10 patients, putaminal reduced uptake was asymmetrical or unilateral. In these 10 cases, six had a unilateral RT corresponding to (crossed) predominant reduced uptake in three cases. In our patients with normal imaging, RT was unilateral in 87.5%.

CONCLUSIONS

This study shows that mixed tremor is a heterogeneous entity. The majority of patients with mixed tremor showed nigrostriatal dysfunction on I123-FP-CIT single-photon emission tomography, suggesting that mixed tremor may be a parkinsonian syndrome rather than a clinical variant of essential tremor.

Для цитирования: de Verdal M, Renard D, Collombier L, Boudousq V, Kotzki P O, Labauge P, Castelnovo G. I123-FP-CIT single-photon emission tomography in patients with long-standing mixed tremor.. European journal of neurology. 2012. DOI: 10.1111/j.1468-1331.2012.03875.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.