MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1017/s0022215111000107

Медицинская библиотека · The Journal of laryngology and otology · 2011

Evoked response audiometry in scrub typhus: prospective, randomised, case-control study.

Thakur J S, Mohindroo N K, Sharma D R, Soni K, Kaushal S S

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To investigate the hypothesis of cochlear and retrocochlear damage in scrub typhus, using evoked response audiometry.

STUDY

DESIGN

Prospective, randomised, case-control study.

METHODS

The study included 25 patients with scrub typhus and 25 controls with other febrile illnesses not known to cause hearing loss. Controls were age- and sex-matched. All subjects underwent pure tone audiometry and evoked response audiometry before commencing treatment.

RESULTS

Six patients presented with hearing loss, although a total of 23 patients had evidence of symmetrical high frequency loss on pure tone audiometry. Evoked response audiometry found significant prolongation of absolute latencies of wave I, III, V, and wave I-III interpeak latency. Two cases with normal hearing had increased interpeak latencies. These findings constitute level 3b evidence.

CONCLUSION

Findings were suggestive of retrocochlear pathology in two cases with normal hearing. In other patients, high frequency hearing loss may have led to altered evoked response results. Although scrub typhus appears to cause middle ear cochlear and retrocochlear damage, the presence of such damage could not be fully confirmed by evoked response audiometry.

Для цитирования: Thakur J S, Mohindroo N K, Sharma D R, Soni K, Kaushal S S. Evoked response audiometry in scrub typhus: prospective, randomised, case-control study.. The Journal of laryngology and otology. 2011. DOI: 10.1017/s0022215111000107.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.