MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00247-022-05333-7

Медицинская библиотека · Pediatric radiology · 2022

Quantifying the contribution of 18F-FDG PET to the diagnostic assessment of pediatric patients with fever of unknown origin: a systematic review and meta-analysis.

Li Qianrui, Tian Rong, Wang Hongxi, Li Ling, Wu Tian, Ren Yan, Su Minggang, Zou Kang, Sun Xin

СтатьяМетаанализСистематический обзорПеревод в очереди

Аннотация

BACKGROUND

The value of 18F-fluorodeoxyglucose positron emission tomography (18F-FDG PET) in the diagnostic assessment of pediatric fever of unknown origin is not known, and evidence from adults is not applicable.

OBJECTIVE

To quantify the contribution of 18F-FDG PET to pediatric fever of unknown origin, considering its diagnostic limitations.

MATERIALS AND

METHODS

We searched PubMed, EMBASE and Cochrane Central Register of Controlled Trials up to Feb. 18, 2021. We included studies on patients with pediatric fever of unknown origin presenting sufficient data to calculate the likelihood of achieving definite diagnosis (based on pathology or clinical follow-up) between those with abnormal PET findings versus those with normal PET findings. We assessed the risk of bias using a modified Newcastle-Ottawa quality assessment scale and quantified the value of PET by pooling the likelihood of achieving definite diagnosis using a random-effects model.

RESULTS

We included 6 studies and found that pediatric patients with abnormal PET findings were about 17 times more likely to achieve definite diagnoses than those with normal PET findings (odds ratio [OR]: 16.75, 95% confidence interval [CI] 8.0-35, P < 0.00001). Sensitivity analyses using a fixed-effect model (OR 16.91, 95% CI 8.1-35, P < 0.0001) or removing one study at a time (OR 12-20, 95% CI lower bound 3.8-8.6, 95% CI upper bound 33-45, P < 0.0001) did not significantly alter the results. Sample size (interaction P = 0.75), imaging modality (interaction P = 0.29), length of follow-up (interaction P = 0.37), fever of unknown origin subclasses (interaction P = 0.89) and geographical areas (interaction P = 0.74) of studies showed no statistically significant influence on the results.

CONCLUSION

18F-FDG PET is a promising approach in the diagnostic work-up of pediatric fever of unknown origin. Further studies are warranted to support routine use in clinical care.

Для цитирования: Li Qianrui, Tian Rong, Wang Hongxi, Li Ling, Wu Tian, Ren Yan, Su Minggang, Zou Kang, Sun Xin. Quantifying the contribution of 18F-FDG PET to the diagnostic assessment of pediatric patients with fever of unknown origin: a systematic review and meta-analysis.. Pediatric radiology. 2022. DOI: 10.1007/s00247-022-05333-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.