MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jchromb.2019.121962

Медицинская библиотека · Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2019

Quantitative bio-analysis of pitavastatin and candesartan in rat plasma by HPLC-UV: Assessment of pharmacokinetic drug-drug interaction.

Patel Misari, Kothari Charmy

СтатьяПеревод в очереди

Аннотация

A novel, precise, accurate and rapid HPLC-UV method was developed, optimised and fully validated for simultaneous estimation of pitavastatin (PIT) and candesartan (CAN) in rat plasma using telmisartan as an internal standard. Following liquid-liquid extraction of the analytes from plasma, chromatographic separation was accomplished on a Waters Reliant C18 column (4.6 × 250 mm, 5 µm) using ACN-5 mM Sodium acetate buffer (80:20, v/v; pH adjusted to 3.5 with acetic acid) as mobile phase at a flow rate of 0.8 mL/min and wavelength of 234 nm. The calibration curves were linear over the concentration ranges of 2-400 ng/mL and 3-400 ng/mL for pitavastatin and candesartan respectively. The method when validated as per US-FDA guidelines was found to be precise as well as accurate. Extraction recovery observed for both analytes was above 90% as well as reproducible and consistent. Stability studies showed the samples to be stable over a long period covering from sample collection to final analysis. The method was successfully applied to investigate pharmacokinetic interaction between PIT and CAN in wistar rats. The mean plasma concentration-time curves of PIT and CAN showed that single PIT as well as CAN show similar pharmacokinetic properties to those obtained when co-administrated with each other (P value >0.05). Hence, there is no evidence for a potential drug-drug interaction between PIT and CAN. This information provides evidence for clinical rational use of CAN and PIT in cardiovascular patients.

Для цитирования: Patel Misari, Kothari Charmy. Quantitative bio-analysis of pitavastatin and candesartan in rat plasma by HPLC-UV: Assessment of pharmacokinetic drug-drug interaction.. Journal of chromatography. B, Analytical technologies in the biomedical and life sciences. 2019. DOI: 10.1016/j.jchromb.2019.121962.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.