MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jjcc.2014.03.014

Медицинская библиотека · Journal of cardiology · 2014

Immediate- and medium-term effects of simultaneous percutaneous corrections of secundum type atrial septal defect combined with pulmonary valve stenosis in local anesthesia and without transesophageal echocardiography guidance.

Xu Xu-Dong, Ding Xue-Yan, Liu Su-Xuan, Bai Yuan, Zhao Xian-Xian, Qin Yong-Wen

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The feasibility and efficacy of simultaneous percutaneous treatment of secundum type atrial septal defect (ASD) combined with pulmonary valve stenosis (PS) have not been proved.

OBJECTIVE

To evaluate the safety and efficacy on the clinical benefit of simultaneous percutaneous correction of these two pathologies under local anesthesia and without transesophageal echocardiography guidance.

METHODS

Transpulmonary gradient, functional status, pulmonary regurgitation (PR), and tricuspid regurgitation (TR) were studied in 35 patients undergoing percutaneous balloon pulmonary valvuloplasty and ASD closure from March 2004 to July 2012. All patients were followed up until January 2013, an average of 39 months.

RESULTS

According to color Doppler transthoracic echocardiography (TTE) before the intervention, the ASD defect size and transpulmonary gradient were 17±8.4 mm and 88±37.8 mmHg, respectively. Post-interventionally, the peak-to-peak transpulmonary gradient decreased from 77±37.6 mmHg to 20±16.2 mmHg (p<0.001) and the ASD occluder size was 23±10.5 mm. In all those patients, there was no residual shunt detected, and moderate and severe TR decreased from 45.7% (16/35) and 20% (7/35) to 8.6% (3/35) and 5.7% (2/35) before and after intervention detected by TTE, respectively. Eight patients had mild PR after procedure and two of them recovered at 6 months and no patient encountered severe adverse events at the latest follow-up.

CONCLUSION

Simultaneous percutaneous corrections of ASD combined with PS are feasible, safe, and effective with satisfactory results.

Для цитирования: Xu Xu-Dong, Ding Xue-Yan, Liu Su-Xuan, Bai Yuan, Zhao Xian-Xian, Qin Yong-Wen. Immediate- and medium-term effects of simultaneous percutaneous corrections of secundum type atrial septal defect combined with pulmonary valve stenosis in local anesthesia and without transesophageal echocardiography guidance.. Journal of cardiology. 2014. DOI: 10.1016/j.jjcc.2014.03.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.