MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.25494

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2014

Transcatheter closure of atrial septal defects in children and adolescents: single-center experience with the GORE® septal occluder.

Grohmann J, Höhn R, Fleck T, Schmoor C, Stiller B

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVES

Device closure of atrial septal defects (ASD II) is an alternative to surgery. ASD morphology and intracardiac relationships may influence device selection. Biocompatibility, techniques for closing large or multiple defects, and the risk of erosion are main issues in children

BACKGROUND

The GORE® Septal Occluder (GSO) is a non-self-centering device with a flat and conformable nitinol-frame covered with expanded polytetrafluoroethylene. We hereby evaluate our initial experience in children to demonstrate feasibility, efficacy, and safety.

METHODS

Single-center retrospective intention-to-treat analysis of GSO procedures in children and adolescents with hemodynamically significant ASD. All procedures were conducted under general anesthesia, fluoroscopy and transesophageal echocardiography. All defects were sized using stop-flow-technique. GSOs of 20-30 mm disc-diameter were implanted.

RESULTS

GSO implantation was attempted in 45 with technical success in 41 patients, median age 6 (range 3-17) years, bodyweight 19 (12-95) kg. Median balloon-sized diameter was 13 (8-19) mm resulting in a GSO-to-ASD-ratio of 2 (1.7-2.5). Deficient retro-aortic rims (<3 mm) were found in 12 patients, and 10 of these 12 defects could be closed. We observed no complications. Four extensive or multiple ASDs were not treated successfully with GSO. After retrieval, one was closed with a different device; three patients needed surgical therapy. The median follow-up of four (range 0.2-22) months was uneventful in all patients

CONCLUSIONS

We found the GSO device closure of ASDs in children to be effective. However, our initial experience is limited to short- and mid-term-follow-up of a low number of patients.

Для цитирования: Grohmann J, Höhn R, Fleck T, Schmoor C, Stiller B. Transcatheter closure of atrial septal defects in children and adolescents: single-center experience with the GORE® septal occluder.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2014. DOI: 10.1002/ccd.25494.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.