Safety and Efficacy Studies of Vertebroplasty, Kyphoplasty, and Mesh-Container-Plasty for the Treatment of Vertebral Compression Fractures: Preliminary Report.

Chen Chen, Li Donghua, Wang Zhiguo, Li Tong, Liu Xunwei, Zhong Jian

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

To evaluate the clinical safety and efficacies of percutaneous vertebroplasty (PVP), percutaneous kyphoplasty (PKP), and percutaneous mesh-container-plasty (PMCP) for the treatment of vertebral compression fractures (VCFs), a retrospective study of 90 patients with VCFs who had been treated by PVP (n = 30), PKP (n = 30), and PMCP (n = 30) was conducted. The clinical efficacies of these three treatments were evaluated by comparing their PMMA cement leakages, cement patterns, height restoration percentages, wedge angles, visual analogue scales (VAS), and oswestry disability index (ODI) at the pre- and post-operative time points. 6.67%, 3.33%, and 0% of patients had PMMA leakage in PVP, PKP, and PMCP groups, respectively. Three (solid, trabecular, and mixed patterns), two (solid and mixed patterns), and one (mixed patterns) types of cement patterns were observed in PVP, PKP, and PMCP groups, respectively. PKP and PMCP treatments had better height restoration ability than PVP treatment. PVP, PKP, and PMCP treatments had significant and similar ability in pain relief and functional recovery ability for the treatment of VCFs. These results indicate minimally invasive techniques were effective methods for the treatment of VCFs. Moreover, these initial outcomes suggest PMCP treatment may be better than both PVP treatment and PKP treatment.

Для цитирования: Chen Chen, Li Donghua, Wang Zhiguo, Li Tong, Liu Xunwei, Zhong Jian. Safety and Efficacy Studies of Vertebroplasty, Kyphoplasty, and Mesh-Container-Plasty for the Treatment of Vertebral Compression Fractures: Preliminary Report.. PloS one. 2016. DOI: 10.1371/journal.pone.0151492.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.