MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jce.16417

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2024

Suture-based techniques versus manual compression for femoral venous haemostasis after electrophysiology procedures.

Mills Mark T, Calvert Peter, Snowdon Richard, Mahida Saagar, Waktare Johan, Borbas Zoltan, Ashrafi Reza, Todd Derick, Modi Simon, Luther Vishal, Gupta Dhiraj

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND AND AIMS: Methods for femoral venous haemostasis following electrophysiology (EP) procedures include manual compression (MC) and suture-based techniques such as a figure-of-eight suture secured with a hand-tied knot (Fo8HT) or a modified figure-of-eight suture secured with a 3-way stopcock (Fo8MOD). We hypothesised that short-term bleeding outcomes using the Fo8MOD approach would be superior to MC. We additionally compared outcomes between Fo8MOD and Fo8HT approaches.

METHODS

We studied consecutive patients undergoing EP procedures at our institution between March and December 2023. Patients were categorised into three haemostasis groups: MC, Fo8HT and Fo8MOD. Access site complications were classified as major (requiring intervention or blood transfusion, delaying discharge or resulting in death) or minor (bleeding/haematoma requiring additional compression).

RESULTS

1089 patients were included: MC 718 (65.9%); Fo8HT 105 (9.6%); Fo8MOD 266 (24.4%). Procedures were most commonly for atrial fibrillation (52.4%), atrial flutter (10.9%), and atrioventricular nodal re-entrant tachycardia (10.1%). In patients receiving periprocedural anticoagulation (865, 79.4%), Fo8MOD associated with fewer complications than MC or Fo8HT (major: MC 2.2%, Fo8HT 6.0%, Fo8MOD 0.8%, p = .01; minor: MC 16.5%, Fo8HT 12.0%, Fo8MOD 7.4%, p = .002). In patients not receiving periprocedural anticoagulation, complications did not differ between haemostasis methods (total major and minor complications 5.8%, p = .729 for between groups rates). On multivariable logistic regression, Fo8MOD was associated with a significantly lower risk of access site complications (OR 0.29 [95% CI 0.17-0.48], p < .001), whilst intraprocedural heparinisation (OR 5.25 [2.88-9.69], p < .001) and larger maximal sheath size (OR 1.06 [1.00-1.11], p = .04) were associated with a higher risk of complications.

CONCLUSION

Femoral haemostasis with Fo8MOD associates with fewer access site complications than MC and Fo8HT following EP procedures that need periprocedural anticoagulation.

Для цитирования: Mills Mark T, Calvert Peter, Snowdon Richard, Mahida Saagar, Waktare Johan, Borbas Zoltan, Ashrafi Reza, Todd Derick, Modi Simon, Luther Vishal, Gupta Dhiraj. Suture-based techniques versus manual compression for femoral venous haemostasis after electrophysiology procedures.. Journal of cardiovascular electrophysiology. 2024. DOI: 10.1111/jce.16417.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.