Inhaled foreign bodies: management according to early or late presentation.

Ibrahim Sersar Sameh, Hamza Usama Ali, AbdelHameed Wael AbdelAziz, AbulMaaty Reda Ahmed, Gowaeli NourEldean Noaman, Moussa Sherif Abdou, AlMorsi Shawki Mahmoud, Hafez Muna Mohammed

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

This retrospective study aims to compare the early and late clinical and management aspects of tracheobronchial aspirated foreign body (AFB), to evaluate the factors associated with delayed diagnosis of foreign body aspiration (FBA) in children and to compare clinical, radiological and bronchoscopic findings in the patients with suspected FBA. A retrospective review of a 10-year experience (from 1995 to 2005). A 1512-bed Mansoura University Hospital and 184-bed Mansoura University Emergency Hospital.

METHODS

The medical records of 3300 patients who underwent bronchoscopy for suspected FBA were reviewed. The data were analysed in three groups: the patients with negative bronchoscopy for FBA (group I), early (group II) and delayed diagnosis (group III). Foreign body was removed using the rigid bronchoscope with or without using the extracting forceps (Egyptian novel technique described in the hand made illustration).

RESULTS

The majority of the patients with FBA were between 3 and 10 years of age. The penetration syndrome and decreased breath sounds were determined in a significantly higher number of the patients with FBA. The plain chest radiography revealed radio-opaque foreign bodies (FBs) in 23.56% of all patients with FBA. Pneumonia and atelectasis were significantly more common in the groups with negative bronchoscopy and with delayed diagnosis (P<0.01). The FBs were most frequently of vegetable origin, such as seeds and peanuts. A significant tissue reaction with inflammation and postbronchoscopic complications were more common in the delayed cases. The novel technique was used since then in 100 cases (4.62%) with a history of FBI (Pins and or small rounded materials). It was successful in 73 (73%) cases of non-impacted inhaled pins. Use of forceps was needed in 21 (21%) cases. Rebronchoscopy despite using both techniques was needed in six (6%) cases within 72h. Failed extraction of the inhaled FB occurred in three cases (3%) for whom bronchotomy was needed.

CONCLUSIONS

Bronchoscopy is indicated on appropriate history and on suspicion. To prevent delayed diagnosis, characteristic symptoms, signs and radiological findings of FBA should be checked in all suspected cases. As clinical and radiological findings of FBA in delayed cases may mimic other disorders, the clinician must be aware of the likelihood of FBA.

Для цитирования: Ibrahim Sersar Sameh, Hamza Usama Ali, AbdelHameed Wael AbdelAziz, AbulMaaty Reda Ahmed, Gowaeli NourEldean Noaman, Moussa Sherif Abdou, AlMorsi Shawki Mahmoud, Hafez Muna Mohammed. Inhaled foreign bodies: management according to early or late presentation.. European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery. 2005. DOI: 10.1016/j.ejcts.2005.05.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.