DOI 10.1016/j.jacep.2024.06.028
The Diagnostic Utility of Holter Monitoring in Catecholaminergic Polymorphic Ventricular Tachycardia.
Аннотация
BACKGROUND
Holter monitoring may raise suspicion of an underlying catecholaminergic polymorphic ventricular tachycardia (CPVT) diagnosis. Although not a primary investigation for CPVT, Holter monitoring is ubiquitously used as a diagnostic tool in the heart rhythm clinic.
OBJECTIVES
The objective of this study was to explore Holter monitoring in CPVT diagnosis.
METHODS
This retrospective cohort study analyzed off-therapy Holter monitoring from 13 ryanodine receptor 2-positive CPVT and 34 healthy patients from the Canadian Hearts in Rhythm Organization national registry. Using the Edwards method, the ratio of ambient-maximum heart rate during Holter monitoring was correlated with exertion level to separate premature ventricular contractions (PVCs) during periods of adrenergic and nonadrenergic stress. A receiver operating characteristic curve analysis determined the optimal threshold for isolating CPVT-induced PVCs during adrenergic states.
RESULTS
PVC burden differed between groups (P = 0.001) but was within population norm, suggesting ambient PVCs are uncommon in CPVT. CPVT patients had higher PVC counts than healthy controls (P = 0.002), with a different distribution based on adrenergic state. The optimal threshold for separating PVCs into periods of adrenergic and nonadrenergic stress in CPVT patients was 76% of the maximum heart rate during the monitoring period. Compared with healthy controls, CPVT patients had a higher PVC count, limited to periods of adrenergic stress, defined by >76% maximum heart rate threshold (P = 0.002; area under the receiver operating characteristic curve: 0.84). Below this threshold, there was no significant PVC difference (P = 0.604).
CONCLUSIONS
Holter monitor PVC counts alone are inadequate for CPVT diagnosis, owing to the adrenergic nature of the disease. Quantifying PVC prevalence at a heart rate threshold >76% identified CPVT with moderate sensitivity (69%) and high specificity (94%).
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.