MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/europace/euae214

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025

Patient selection, ventricular tachycardia substrate delineation, and data transfer for stereotactic arrhythmia radioablation: a clinical consensus statement of the European Heart Rhythm Association of the European Society of Cardiology and the Heart Rhythm Society.

Zeppenfeld Katja, Rademaker Robert, Al-Ahmad Amin, Carbucicchio Corrado, De Chillou Christian, Cvek Jakub, Ebert Micaela, Ho Gordon, Kautzner Josef, Lambiase Pier, Merino Jose Luis, Lloyd Michael, Misra Satish, Pruvot Etienne, Sapp John, Schiappacasse Luis, Sramko Marek, Stevenson William G, Zei Paul C, Wichterle Dan, Chrispin Jonathan, Siklody Claudia Herrera, Neuwirth Radek, Pelargonio Gemma, Reichlin Tobias, Robinson Clifford, Tondo Claudio

СтатьяConsensus StatementПеревод в очереди

Аннотация

Stereotactic arrhythmia radioablation (STAR) is a novel, non-invasive, and promising treatment option for ventricular arrhythmias (VAs). It has been applied in highly selected patients mainly as bailout procedure, when (multiple) catheter ablations, together with anti-arrhythmic drugs, were unable to control the VAs. Despite the increasing clinical use, there is still limited knowledge of the acute and long-term response of normal and diseased myocardium to STAR. Acute toxicity appeared to be reasonably low, but potential late adverse effects may be underreported. Among published studies, the provided methodological information is often limited, and patient selection, target volume definition, methods for determination and transfer of target volume, and techniques for treatment planning and execution differ across studies, hampering the pooling of data and comparison across studies. In addition, STAR requires close and new collaboration between clinical electrophysiologists and radiation oncologists, which is facilitated by shared knowledge in each collaborator's area of expertise and a common language. This clinical consensus statement provides uniform definition of cardiac target volumes. It aims to provide advice in patient selection for STAR including aetiology-specific aspects and advice in optimal cardiac target volume identification based on available evidence. Safety concerns and the advice for acute and long-term monitoring including the importance of standardized reporting and follow-up are covered by this document. Areas of uncertainty are listed, which require high-quality, reliable pre-clinical and clinical evidence before the expansion of STAR beyond clinical scenarios in which proven therapies are ineffective or unavailable.

Для цитирования: Zeppenfeld Katja, Rademaker Robert, Al-Ahmad Amin, Carbucicchio Corrado, De Chillou Christian, Cvek Jakub, Ebert Micaela, Ho Gordon, Kautzner Josef, Lambiase Pier, Merino Jose Luis, Lloyd Michael, Misra Satish, Pruvot Etienne, Sapp John, Schiappacasse Luis, Sramko Marek, Stevenson William G, Zei Paul C, Wichterle Dan, Chrispin Jonathan, Siklody Claudia Herrera, Neuwirth Radek, Pelargonio Gemma, Reichlin Tobias, Robinson Clifford, Tondo Claudio. Patient selection, ventricular tachycardia substrate delineation, and data transfer for stereotactic arrhythmia radioablation: a clinical consensus statement of the European Heart Rhythm Association of the European Society of Cardiology and the Heart Rhythm Society.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2025. DOI: 10.1093/europace/euae214.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.