MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.24768

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2013

Comparison of the results of transcatheter closure of patent ductus arteriosus with newer Amplatzer devices.

Liddy Stephen, Oslizlok Paul, Walsh Kevin P

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVES

To compare the success and complication rates for the different devices and patent ductus arteriosus (PDA) types.

BACKGROUND

There are numerous devices available for transcatheter closure of PDA but data comparing the success and complication rates of the newer devices are lacking.

METHODS

A retrospective review was undertaken of all cases of transcatheter PDA closure at a tertiary referral center.

RESULTS

Transcatheter PDA closure was achieved in 176 of 177 cases. Mean age, weight, and minimum ductal diameter were 3.3 years, 15.0 kg, and 2.5 mm, respectively. Devices used were Amplatzer Duct Occluder I (ADO I, 50.3%), Amplatzer Duct Occluder II (ADO II, 28.2%), Amplatzer Duct Occluder II Additional Sizes (ADO II AS, 5.1%), flipper coils (14.1%), and "other" devices (2.3%). Regarding Amplatzer devices, arterial delivery had a significantly shorter fluoroscopy time as compared to venous delivery (3.7 vs. 5.0 min, P = 0.0068), with no significant difference in outcomes. Immediate residual shunt rates were 7.9% (7/89) for ADO I, 4.1% (2/49) for ADO II, 11.1% (1/9) for ADO II AS, and 0% (0/25) for flipper coils. Aortic protrusion rates were 9% (8/89) for ADO I, 14.3% (7/49) for ADO II, and O% for both ADO II AS (0/9) and flipper coils (0/25).

CONCLUSIONS

All devices achieved excellent occlusion rates with low complication rates, regardless of PDA type. Device delivery via arterial access was associated with a shorter fluoroscopy time as compared to venous delivery, with no significant difference in outcomes. ADO II AS may be preferable to ADO II in the younger infant.

Для цитирования: Liddy Stephen, Oslizlok Paul, Walsh Kevin P. Comparison of the results of transcatheter closure of patent ductus arteriosus with newer Amplatzer devices.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2013. DOI: 10.1002/ccd.24768.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.