INTRODUCTION

We report a novel technique to measure the length of the rectourethral fistula (RUF) in male patients with high-/intermediate-type imperforate anus during laparoscopically assisted anorectal pull-through (LAARP) to prevent incomplete excision.

METHOD: During LAARP for RUF in 5 male patients (mean age, 4.6 months; prostatic in 3, bulbar in 2), the RUF was dissected carefully close to the urethra and opened; and a fine catheter with 10-mm calibrations was inserted by the laparoscopic surgeon until it was seen to emerge at or near the verumontanum by another surgeon performing cystoscopy. The laparoscopic surgeon then measured the distance from the point where dissection was ceased at the rectal end to the urethral orifice. The RUF was dissected free from the prostate for exactly this length, tied, and excised; and colon pull-through was performed to finish LAARP.

RESULT: Rectourethral fistulae ranged from 5 to 15 mm and were much longer than expected. All dissections were uncomplicated without any injury to the urethra, and postoperative courses were unremarkable. At mean follow-up of 11 months, urination is normal in all without evidence of residual fistula.

CONCLUSION

Knowing the exact length of the RUF facilitates safe and complete excision in an otherwise blind situation.

Для цитирования: Koga Hiroyuki, Kato Yoshifumi, Shimotakahara Akihiro, Miyano Go, Lane Geoffrey J, Okazaki Tadaharu, Yamataka Atsuyuki. Intraoperative measurement of rectourethral fistula: prevention of incomplete excision in male patients with high-/intermediate-type imperforate anus.. Journal of pediatric surgery. 2010. DOI: 10.1016/j.jpedsurg.2009.10.085.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.