MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jbiomech.2015.06.026

Медицинская библиотека · Journal of biomechanics · 2015

Biomechanics of low-modulus and standard acrylic bone cements in simulated vertebroplasty: A human ex vivo study.

Holub Ondrej, López Alejandro, Borse Vishal, Engqvist Håkan, Kapur Nik, Hall Richard M, Persson Cecilia

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The high stiffness of bone cements used in vertebroplasty has been hypothesised to contribute to the propensity of adjacent vertebral fractures after treatment. Therefore, new low-modulus cements have been developed; however, there are currently no studies assessing the biomechanical aspects of vertebroplasty with these cements in an ex vivo non-prophylactic model. In this study, we induced wedge fractures through eccentric uniaxial compression to single whole-vertebrae, before and after augmentation with either standard or low-modulus cement. Compressive strength and stiffness of individual vertebrae were measured, on 19 samples from metastatic spines and 20 samples from elderly, osteopenic spines. While both cement types increased the strength of both the metastatic (+34% and +63% for standard and low-modulus cement, respectively) and the elderly vertebrae (+303% and +113%, respectively), none of them restored the initial stiffness of metastatic specimens (-51% and -46%, respectively). Furthermore, low-modulus cement gave a lower total stiffness (-13%) of elderly specimens whereas standard cement increased it above initial levels (+17%). Results show that vertebroplasty with low-modulus cement could provide restoration of the initial stiffness while increasing the strength of fractured elderly vertebrae and hence represent a treatment modality which is closer to pre-augmented behaviour. Also, this study indicates that stiffness-modified cement needs to be optimised for patient/pathology specific treatment.

Для цитирования: Holub Ondrej, López Alejandro, Borse Vishal, Engqvist Håkan, Kapur Nik, Hall Richard M, Persson Cecilia. Biomechanics of low-modulus and standard acrylic bone cements in simulated vertebroplasty: A human ex vivo study.. Journal of biomechanics. 2015. DOI: 10.1016/j.jbiomech.2015.06.026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.