JACC. Clinical electrophysiology · 2024
Effect of Ablation Energy Source on Outcomes of Slow Pathway Modification for AVNRT in Children.
СтатьяСравнительное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Shah Maully J, Baskar Shankar, Kennedy Kevin F, Spar David S, Behere Shashank, Czosek Richard J, Janson Christopher M
Аннотация
BACKGROUND: Selection of radiofrequency ablation (RF) or cryoablation (Cryo) for atrioventricular nodal re-entrant tachycardia (AVNRT) in children remains controversial due to a lack of contemporary comparison studies in this population.
OBJECTIVES: This study sought to compare outcomes of RF and Cryo for AVNRT in the pediatric population.
METHODS: AVNRT ablation outcomes were retrospectively analyzed utilizing the National Cardiovascular Data Registry IMPACT (Improving Pediatric and Adult Congenital Treatment) Registry from April 2016 to March 2019. Data from subjects 1 to 21 years of age undergoing elective first-time slow pathway (SP) modification for AVNRT were included. Exclusion criteria included <1 year of age, congenital heart disease, and >1 ablation target. Cases were analyzed by ablation energy: 1) RF only; 2) Cryo only; 3) radiofrequency ablation switching to cryoablation (RF→Cryo); and 4) cryoablation switching to radiofrequency ablation (Cryo→RF). The primary outcome was acute ablation failure. Secondary outcomes included in-hospital adverse events.
RESULTS: Among 2,448 patients (mean age 13.6 ± 3.4 years, 60% female), RF only was employed in 43% (n = 1,046), Cryo only in 49% (n = 1,201), RF→Cryo in 6% (n = 135), and Cryo→RF in 66 (3%). Acute ablation failure occurred in 1.3% (n = 33), with no difference by energy source (1% in RF only, 1.5% in Cryo only, 1.5% in RF→Cryo, 3% in Cryo→RF; P = 0.5). Atrioventricular (AV) block requiring permanent pacemaker did not occur in any group; transient AV block occurred in 0.4% of the cohort, with no difference by group.
CONCLUSIONS: In this largest pediatric study of AVNRT ablation, RF and Cryo demonstrated comparable high acute success and rare documentation of AV block that did not result in temporary or permanent pacing. Longitudinal data are important for further comparison of these modalities with regard to recurrence risk and late complications.
OBJECTIVES: This study sought to compare outcomes of RF and Cryo for AVNRT in the pediatric population.
METHODS: AVNRT ablation outcomes were retrospectively analyzed utilizing the National Cardiovascular Data Registry IMPACT (Improving Pediatric and Adult Congenital Treatment) Registry from April 2016 to March 2019. Data from subjects 1 to 21 years of age undergoing elective first-time slow pathway (SP) modification for AVNRT were included. Exclusion criteria included <1 year of age, congenital heart disease, and >1 ablation target. Cases were analyzed by ablation energy: 1) RF only; 2) Cryo only; 3) radiofrequency ablation switching to cryoablation (RF→Cryo); and 4) cryoablation switching to radiofrequency ablation (Cryo→RF). The primary outcome was acute ablation failure. Secondary outcomes included in-hospital adverse events.
RESULTS: Among 2,448 patients (mean age 13.6 ± 3.4 years, 60% female), RF only was employed in 43% (n = 1,046), Cryo only in 49% (n = 1,201), RF→Cryo in 6% (n = 135), and Cryo→RF in 66 (3%). Acute ablation failure occurred in 1.3% (n = 33), with no difference by energy source (1% in RF only, 1.5% in Cryo only, 1.5% in RF→Cryo, 3% in Cryo→RF; P = 0.5). Atrioventricular (AV) block requiring permanent pacemaker did not occur in any group; transient AV block occurred in 0.4% of the cohort, with no difference by group.
CONCLUSIONS: In this largest pediatric study of AVNRT ablation, RF and Cryo demonstrated comparable high acute success and rare documentation of AV block that did not result in temporary or permanent pacing. Longitudinal data are important for further comparison of these modalities with regard to recurrence risk and late complications.